CV
Discription
01
Address
02
PoM Minimum Speed
03
PoM Acceleration delay
04
PoM Braking delay
05
PoM Maximum speed
08
Factory Reset / Manufacturer Recognition
13
PoM Functions F1 - F8 in analog operation
14
PoM Functions F9 - F15 and lights in analog operation
17
Extended address (upper part CV29 Bit 5 = 1)
18
Extended address (lower part CV29 Bit 5 = 1)
19
Multiple Unit Address
21
PoM Functions F1 - F8 on Multiple Unit
22
PoM Functions F9 - F15 and lights on Multiple Unit
Bit 0: Reversing direction
Bit 1: Number of speed levels 14 or 28/128
29
Bit 2: DCC operation with braking area
Bit 5: Address length 7 Bit / 14 Bit
Alternative Formats
Bit 0 analog AC
50
PoM
Bit 1 analog DC
Bit 2 Motorola
Bit 3 mfx
Betrieb • Operation • Fonctionnement
6021 Value
01 – 80
—
01 – 63
01 – 63
01 – 63
08
—
—
—
—
—
—
—
—
—
12
DCC Value
1 – 127 (3)
CV 29/Bit 5 = 0
0 – 255 (5)
0 – 255 (6)
0 – 255 (6)
0 – 255 (213)
08 (131)
0 – 255 (0)
0 – 255 (1)
192 – 231 (192)
0 – 255 (128)
0 – 255 (0)
0 – 255 (0)
0 – 255 (0)
0 / 1 (0)*
0 / 2 (2)*
0 / 4 (4)*
0 / 32 (0)*
0 / 1 (1)*
0 / 2 (2)*
0 / 4 (4)*
0 / 8 (8)*
Exploitatie • Operación • Operazione