GB
6.3.7
Aluminium (Mg5) ER5356 100%Ar; spray arc
Sheet T
[inch]
3/16
3/16
1/4
1/4
3/8
3/8
1/2
1/2
7
MAINTENANCE
Regular maintenance is important for safe, reliable operation.
Maintenance must be executed by a professional.
Only those persons who have appropriate electrical knowledge (authorised
personnel) may remove the safety plates.
Note!
All guarantee undertakings from the supplier cease to apply if the customer himself
attempts any work in the product during the guarantee period in order to rectify any
faults.
7.1
Inspection and cleaning
Check regularly that the power source is free from dirt.
The power source should be regularly blown clean using dry compressed air at reduced
pressure. More frequently in dirty environments.
Otherwise the air inlet/outlet may become blocked and cause overheating. To avoid
this you can use an airfilter.
The airfilter is an accessory. Ordering number can be found on page 38.
Welding gun
Cleaning and replacement of the welding gun's wear parts should take place at
S
regular intervals in order to achieve trouble–free wire feed. Blow the wire guide
clean regularly and clean the contact tip.
C420e1
All manuals and user guides at all-guides.com
Feed
Wire j
speed
[inch]
[inch/min]
0,045
470
0,063
–
0,045
530
0,063
290
0,045
610
0,063
340
0,045
760
0,063
410
– 15 –
Coarse step
Fine step
230/460/575V
230/460/575V
1–5
1–7
4 / 4 / 4
6 / 5 / 4
–
–
4 / 4 / 4
7 / 6 / 6
4 / 4 / 4
6 / 5 / 4
5 / 5 / 5
2 / 2 / 2
5 / 4 / 4
1 / 7 / 7
5 / 5 / 5
4 / 4 / 4
5 / 5 / 5
3 / 3 / 3
Return
cable
socket
–