Draw a mid location line from the ceiling perpendicular to the lower
edge of the hood ().
There is a tab in the middle of the flue connection plate. Place the
middle point of this tab on the line that is drawn perpendicular to
the wall. Align horizontally and mark the holes where the connec-
tion plate will be mounted via a pen (/a).
Drill the marked points with Ø 6 mm drill and insert 2 pieces of Ø 6
mm plastic dowels in the drilled holes (/a).
Fix the flue connection plate to the wall with 3,9x22 screws (/a).
To drill the suspension holes of the flue, place the mounting tem-
plate on the surface where the appliance will be mounted on and
mark the mounting holes (/b).
Drill the suspension holes with Ø 8 mm drill and place the dowels
(/b).
Screw in 2 pieces of 4.8x50 hanger screws so that there is a 5 mm
gap between the screw head and the wall (/b).
It is necessary to open the filter. Metal grease filters must be
removed. In the event that the diameter of the exhaust air pipe is
less than 150 mm, install the Ø 150/120 mm chimney adapter.
Hold the appliance by its body and place it on the suspension
screws on the wall and tighten the screws ().
Fix the appliance with 4.8x50 screws through the mounting hole on
the interior of the appliance ().
Install the aluminum oil filters of the device. Install the air outlet
pipe.