SETTING HOT WATER TEMPERATURE
O
Hot water temperature can be set between 40 to 65°C. Set the temperature depending on hot water
volume that you require. The recommended temperature range is 40 to 55°C. (The factory default setting
is 55°C.) A low water temperature setting will mean more effi cient operation. A higher temperature setting
will make more scale.
Estimated hot water volume when converted to 40°C
Hot water temperature
Hot water volume when converted to 40°C
O
The operation mode will automatically change depending on the hot water setting temperature.
Hot water temperature
Heat pump operation
Electric heater operation
( 1): Heat pump may not operate depending on the condition of outdoor temperature and tank water
temperature.
Air temperature is below -15°C or above 37°C, the heat pump does not operate for the compressor
protection.
( 2): Electric heater will operate in case that heating capacity of heat pump operation is not enough to
heat up the water to setting temperature.
1
Press the
button to display hot water temperature setting.
2
Press the
button.
The hot water temperature setting starts to blink.
Press the
3
setting.
Hold down the buttons to rapidly increase or decrease the
number values.
Press the
button.
4
This sets the hot water temperature.
After about 10 seconds, the indicator will alternately display
current water temperature and the time.
All manuals and user guides at all-guides.com
40°C
240L
buttons to adjust hot water temperature
45°C
50°C
295L
345L
~ 55°C
ON ( 1)
OFF/ON ( 2)
– 10 –
55°C
60°C
65°C
395L
430L
465L
55 ~ 65°C