Troubleshooting
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless
testing requires power.
Diagnostic Codes
Code Description
Trigger
1
Dryer
The
Thermistor
Thermistor
Short Sensed
resistance is
very low.
2
Thermistor
The
Open Sensed
Thermistor
resistance is
very high
3
Door Circuit
Invalid state
Failure
for more
than 256
milliseconds
4
Possible
If either
motor
motor
transistor
transistor is
error
seen open or
shorted
during startup
Stuck Key
A key is
8
sensed to be
pressed
more than
75 seconds,
the key shall
be assumed
to be stuck.
All manuals and user guides at all-guides.com
WARNING
Action Taken
Check for:
- Clogged lint
screen.
- Restricted vent
system.
- Check Thermistor
resistance.
Display Fault/Error Codes
Check for:
- Low ambient
Display Description
temperature in
room (Below
50°F/10°C).
- Outside vent
damper is stuck
open in wintertime.
- Loose or open
wire terminals.
- Check Thermistor
resistance.
Check for:
- Loose or open
wire terminals in
Door Sense circuit.
Check for:
- Loose connections
in motor circuit.
- Run System
Check Mode and
check the motor
relay function.
- If relay functions,
disregard the
diagnostic code.
- If relay does not
function, replace
machine control
board.
Run membrane pad
check and replace
console w/membrane
pad if necessary.
5
Code Description
Trigger
10
No Wet
Sensor bar
Clothes
detects no wet
clothes while a
Sensor Dry
Cycle
Trigger
tS
Dryer
The
Thermistor
Thermistor
Short Sensed
resistance is
very low.
do
Door Open
Running the
dryer with
door open
FE
Power source
Invalid power
frequency
source
Error
Frequency
Door Circuit
Invalid state
dC
Failure
for more than
256
milliseconds
Heating Error Invalid
hE
heating
temperature
in running the
dryer
Action Taken
Check for:
- Running dryer with
no wet clothes in
sensor dry cycle
Action Taken
Check for:
- Clogged lint
screen.
- Restricted vent
system.
- Check Thermistor
resistance.
- Check for
diagnostic code 1
Check for:
- Close the door,
and run the dryer
- Loose or open
wire terminals in
Door Sense
circuit.
- Check for
diagnostic code 3
Check for:
- Not using regular
power source
frequency
- Invalid power
frequency sense
circuit
Check for:
- Loose or open
wire terminals in
Door Sense
circuit.
- Check for
diagnostic code 3
Check for:
- Restricted vent
system.
- Check
Thermistor
resistance.
W10162408