29" (73.7 CM) GAS DRYER INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION DE LA SÉCHEUSE
DRYER SAFETY ............................................... 1
INSTALLATION INSTRUCTIONS.................... 2
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite:
www.whirlpool.com.
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la
puerta.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
W10150630A
À GAZ DE 29" (73,7 CM)
Table of Contents / Table des matières
Tools and Parts ............................................. 2
Location Requirements................................. 3
Electrical Requirements ................................ 4
Gas Supply Requirements ............................ 4
Venting Requirements................................... 5
Plan Vent System .......................................... 6
Install Vent System........................................ 7
Install Leveling Legs...................................... 7
Make Gas Connection .................................. 8
Connect Vent................................................. 8
Level Dryer .................................................... 8
Reverse Door Swing (Optional)..................... 9
Complete Installation .................................. 10
Your safety and the safety of others are very important.
DANGER
IMPORTANT SAFETY INSTRUCTIONS
When discarding or storing your old clothes dryer, remove the door.
SAVE THESE INSTRUCTIONS
SÉCURITÉ DE LA SÉCHEUSE ......................11
Outillage et pièces nécessaires ...................12
Exigences d'installation ...............................12
Spécifications électriques............................13
Raccordement au gaz..................................18
Mise à niveau de la sécheuse......................18
la porte (facultatif) ........................................19
Achever l'installation ....................................20
DRYER SAFETY
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.

Publicité

Table des Matières
loading

Sommaire des Matières pour Amana NGD5200TQ0

  • Page 1: Table Des Matières

    29" (73.7 CM) GAS DRYER INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION DE LA SÉCHEUSE À GAZ DE 29" (73,7 CM) Table of Contents / Table des matières DRYER SAFETY ..........1 SÉCURITÉ DE LA SÉCHEUSE ......11 INSTALLATION INSTRUCTIONS....2 INSTRUCTIONS D’INSTALLATION....12 Tools and Parts ..........2 Outillage et pièces nécessaires ....12 Location Requirements.........
  • Page 2: What To Do If You Smell Gas

    WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 3: Installation Clearances

    Location Requirements Dryer Dimensions WARNING 15¼" 22¾" (38.74cm) 43³⁄₈" (57.8cm) 43³⁄₈" (110cm) (110cm) *27¾" Explosion Hazard *26" (70.5cm) (66cm) Keep flammable materials and vapors, such as 29" 29" (73.66cm) (73.66cm) gasoline, away from dryer. Place dryer at least 18 inches (46 cm) above the floor for a garage installation.
  • Page 4: Electrical Requirements

    Mobile Home - Additional Installation Requirements Gas Supply Requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 WARNING (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or the Canadian Manufactured Home Standard, CAN/CSA-Z240 MH.
  • Page 5: Venting Requirements

    In the U.S.A.: Venting Requirements An individual manual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. WARNING In Canada: An individual manual shutoff valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code.
  • Page 6: Plan Vent System

    Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor Plan Vent System performance. Do not install flexible metal vent in enclosed walls, ceilings or Choose your exhaust installation type floors. Recommended exhaust installations Elbows Typical installations vent the dryer from the rear of the dryer.
  • Page 7: Install Vent System

    NOTE: The following kits for close clearance alternate installations Vent system chart are available for purchase. Please see the “Assistance or Service” NOTE: Side and bottom exhaust installations have a 90º turn section of the Dryer User Instructions. inside the dryer. To determine maximum exhaust length, add one Over-the-Top Installation: 90º...
  • Page 8: Make Gas Connection

    2. Firmly grasp the body of the dryer (not the top or console A combination of pipe fittings must be used to connect the panel). Gently lay the dryer on the cardboard. dryer to the existing gas line. Shown is a recommended connection.
  • Page 9: Reverse Door Swing (Optional)

    Reverse Door Swing (Optional) You can change your door swing from a right-side opening to a 2. Open dryer door. Remove bottom screws from cabinet side of left-side opening, if desired. hinges (D). Loosen (do not remove) top screws from cabinet side of hinges.
  • Page 10: Complete Installation

    Complete Installation 1. Check that all parts are now installed. If there is an extra part, 6. Remove any protective film or tape remaining on the dryer. go back through the steps to see which step was skipped. 7. Dispose of/recycle all packaging materials. 2.
  • Page 11: Sécurité De La Sécheuse

    INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE À GAZ DE (73,7 CM) 29" SÉCURITÉ DE LA SÉCHEUSE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité...
  • Page 12: Instructions D'installation

    IMPORTANT : L'installation du gaz doit se conformer aux codes locaux, ou en l'absence de codes locaux, au code canadien d'installation B149.1 du gaz naturel ou du propane. La sécheuse doit être électriquement reliée à la terre conformément aux codes locaux, ou en l'absence de codes locaux, au Code canadien de l'électricité, CSA C22.1.
  • Page 13: Espacements D'installation

    Espacements d’installation Il faut aussi prendre en compte l’espace requis entre les appareils voisins. L’emplacement doit être assez grand pour permettre d’ouvrir complètement la porte de la sécheuse. 3"* (7,6 cm) 14" max* Dimensions de la sécheuse 48 po (35,6 cm) (310 cm ) 18"* (45,7 cm)
  • Page 14: Spécifications De L'alimentation En Gaz

    Cette sécheuse doit être équipée du brûleur convenable, INSTRUCTIONS DE LIAISON À LA TERRE correspondant au gaz spécifique qui alimente l’habitation. L’information sur le brûleur se trouve sur la plaque Pour une sécheuse reliée à la terre et connectée par signalétique dans le logement de la porte de la sécheuse.
  • Page 15: Exigences Concernant L'évacuation

    On doit raccorder la sécheuse à la conduite d’alimentation en gaz à l’aide d’un connecteur de gaz flexible homologué qui En cas d'utilisation du système d'évacuation existant respecte les normes applicables aux connecteurs utilisés avec des appareils ménagers à gaz, ANSI Z21.24 ou Éliminer la charpie sur toute la longueur du système et veiller à...
  • Page 16: Planification Du Système D'évacuation

    Brides de serrage Planification du système d’évacuation Utiliser des brides pour sceller tous les joints. Le conduit d'évacuation ne doit pas être connecté ou fixé avec des vis ou avec tout autre dispositif de serrage qui se Choisir un type de système d’évacuation prolonge à...
  • Page 17: Installation Du Système D'évacuation

    REMARQUE : On peut acheter les trousses suivantes pour les Nombre de Type de Clapets de Clapets installations où le dégagement est réduit. Veuillez consulter la change- conduit type boîte ou inclinés section “Assistance ou service” dans les Instructions pour ments de à...
  • Page 18: Raccordement Au Gaz

    2. Saisir fermement la sécheuse par la caisse (ni par le dessus ni On doit utiliser une combinaison de raccords de tuyauterie par le panneau de commande). Placer soigneusement la pour raccorder la sécheuse à l’alimentation en gaz existante. sécheuse sur le carton. On voit ci-dessous une illustration d’un raccordement recommandé.
  • Page 19: Inversion Du Sens D'ouverture De La Porte (Facultatif)

    Inversion du sens d'ouverture de la porte (facultatif) On peut changer l’ouverture de la porte du côté droit au côté Porte réversible extra-large à pivotement latéral gauche si désiré. Grande porte réversible à pivotement latéral 1. Placer une serviette (A) sur la sécheuse pour protéger la surface.
  • Page 20: Achever L'installation

    8. Enlever la gâche de la porte (E) de la caisse. Utiliser un petit 10. Enlever le bouchon d’obturation de la gâche de la porte (B). tournevis à lame plate pour ôter soigneusement 4 bouchons Insérer dans le trou la gâche qui a été enlevée à l’étape 8; fixer d’obturation (F) du côté...

Table des Matières