10 Faults and troubleshooting
10 Faults and troubleshooting
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► Ensure that all seals on the device are free from dirt and debris.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Do not open the dust collecting drawer until at least one minute has passed since the device was
switched off.
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
or a damp cloth.
► Observe the documentation for the welding components.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 3
Faults and troubleshooting
Fault
Extraction volume too low.
External extraction system
does not start.
Dust escapes from the dust
collecting drawer.
EN - 24
WARNING
Cause
Filter elements saturated.
Dust collecting drawer not properly sealed.
Extraction hose blocked.
Extraction hose defective.
The quick lock is not mounted correctly.
The star screws are not mounted correctly.
The power supply is faulty.
Electrical components defective.
Automatic mode, current clamp is not mounted
correctly.
Dust collecting drawer not properly sealed.
Dust collecting drawer full.
The quick lock is not mounted correctly.
The star screws are not mounted correctly.
xFUME™ ADVANCED HP 230V – CSA
Troubleshooting
► Replace the filter cartridges.
 9.3 Replacing filter cartridges on
page EN-21
► Check and install correctly.
 9.2 Emptying the dust collecting drawer
on page EN-20
► Clean the extraction hose.
► Replace the extraction hose.
 6.1 Attaching the extraction hose on
page EN-12
► Mount the quick lock correctly.
► Tighten the star screws by hand.
► Check and replace as needed, or contact
customer service.
► Mount the current clamp properly.
 6.2 Mounting the current clamp on
page EN-13
► Check and install correctly.
 9.2 Emptying the dust collecting drawer
on page EN-20
► Empty the dust collecting drawer.
 9.2 Emptying the dust collecting drawer
on page EN-20
► Mount the quick lock correctly.
► Tighten the star screws by hand.