xFUME™ ADVANCED HP 230V – CSA
9.3 Replacing filter cartridges
NOTICE
Damage to the rotary nozzle
Damage to the rotary nozzle due to improper removal and replacement of filter cartridges.
► Unscrew the filter cartridges without tilting and remove the filter cartridges concentrically from the
housing, avoiding contact with the rotary nozzle.
► Insert the filter cartridges concentric to the rotary nozzle and screw them in without tilting.
9 Maintenance and cleaning
Loosen the bottom clamp on both sides. Loosen
1
the side clamp on both sides, remove the housing
and set to the side.
Slide the dust collecting bag over the filter
2
cartridges.
Loosen the filter cartridges, unscrew them and
3
remove them concentric to the rotary nozzle.
Ensure that the filter cartridges are not tilted.
Pack the filter cartridges in the dust collecting bag
4
and seal in such a way that dust cannot get in (pull
rope/cable tie).
Dispose of the dust collecting bag in accordance
5
with local regulations.
12 Disposal on page EN-27
Insert the new filter cartridge concentric to the
6
rotary nozzle.