9 Maintenance and cleaning
9.1 Maintenance and cleaning intervals
The specified intervals are standard values and refer to single-shift operation. We recommend recording the
inspections. The date of the inspection, the detected defects and the name of the inspector must be observed.
After 2 operating hours or
no later than when the
service LED illuminates
Daily
Weekly
Monthly
After approx.
500 operating hours
9.2 Emptying the dust collecting drawer
Health risk caused by inhaling harmful dust
Improper emptying of the dust collecting drawer can lead to harmful dust and debris penetrating the
ambient air. It can harm the respiratory tract if inhaled.
► Empty the dust collecting drawer into a dust collecting bag immediately after removal.
► Do not clean the device with compressed air.
EN - 20
► Run the cleaning process.
 7 Operation on page EN-15
► Replace filter cartridges.
 9.3 Replacing filter cartridges on page EN-21
► Empty the dust collecting drawer.
 9.2 Emptying the dust collecting drawer on page EN-20
► Check the operating hours meter.
► Check device for visible damage.
► Turbines must be replaced only by a qualified electrician.
 9.4 Replacing the turbines on page EN-23
WARNING
xFUME™ ADVANCED HP 230V – CSA
Loosen the star screws on the dust collecting
1
drawer.
Empty the dust collecting drawer into a dust
2
collecting bag.
Close the dust collecting bag and dispose of it in
3
accordance with local regulations.
 12 Disposal on page EN-27
Reassemble in the reverse order and ensure that
4
the star screws are tightened by hand.