Cabling examples
MFE180-04xx-02A5...016A-4
3
MFE180-04xx-024A...090A-4
3
4
All manuals and user guides at all-guides.com
1
2
1
2
Cable clamp on bare shield.
1
PE/Ground connection.
2
Between cable clamp and terminals, cover bare
3
shield with insulating tape.
Screw lug detail:
4
Wire sizes accepted by power terminals
Drive type MFE180-04xx...
-02A5...07A0-4
-09A5...016A-4
-024A...090A-4
Tightening torques
Power terminals (supply,
motor, and braking resistor
Drive type
cables)
MFE180-04xx...
N·m (lbf·in)
-02A5...07A0-4
0.5 ... 0.6 (4.4 ... 5.3)
-09A5...016A-4
1.2 ... 1.5 (10.6 ... 13.3)
-024A...090A-4
3 (25)
PE/Ground
Drive type
terminals
MFE180-04xx...
N·m (lbf·in)
-02A5...07A0-4
1.5 (13)
-09A5...016A-4
1.5 (13)
-024A...090A-4
3 (25)
Quick installation guide - MotiFlex e180
5
Wire size
2
0.25 ... 4 mm
2
0.5 ... 6 mm
2
6 ... 70 mm
Screw lug
(Allen screw)
N·m (lbf·ft)
N/A
N/A
15 (11)
Power
Power cable
connector
clamps
covers
N·m (lbf·in)
N·m (lbf·in)
1.5 (13)
N/A
1.5 (13)
N/A
1.5 (13)
3 (25)