Installation
MOUNTING AND WIRING THE SAFETY REVERSING SENSORS
1
Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor.
Use wing nuts to fasten safety reversing sensors to brackets, with lenses pointing
2
toward each other across the door. Be sure the lens is not obstructed by a bracket
extension.
3
Finger tighten the wing nuts.
Wing Nut
4
Run the wires from both safety reversing sensors to the opener. Use insulated staples
to secure wire to wall and ceiling.
Strip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/
5
black wires suffi ciently to connect to the opener quick-connect terminals: white to
white and white/black to grey.
7/16
(11 mm)
WHITE/
BLACK
WHITE
Carriage Bolt
Bell wire
17
HARDWARE
Carriage Bolt
1/4"-20x1/2"
Wing Nut
1/4"-20
HARDWARE
Staple