Functions
Underscan mode
The signal normally scanned outside of the screen can
be monitored in the underscan mode.
Note
When the monitor is in the underscan mode, the dark
RGB scanning lines may appear on the top edge of the
screen. These are caused by an internal test signal,
rather than the input signal.
Horizontal/vertical delay mode
The horizontal and vertical sync signals can be
checked simultaneously in the H/V delay mode.
Auto/manual degaussing
Degaussing of the screen can be performed
automatically when the power is turned on, or
manually by pressing the DEGAUSS button.
On-screen menus
You can set color temperature, CHROMA SET UP,
and other settings by using the on-screen menus.
Caption vision decoder (Only for PVM-
20S1WU)
If the video signals are encoded with caption vision
signals, captions can be superimposed on the monitor
screen. You can select the caption type or switch off
the caption vision, by using the on-screen menus.
Five menu languages
You can select the menu language from among five
languages on the menu.
SDI (Serial Digital Interface) Kit
By using the following optional SDI Kits, the monitor
can display SMPTE 259M 4:2:2 serial digital signal
from a digital VCR. (ex. Sony 4:2:2 VCR)
– BKM-101C: Component SDI Kit (for video)
– BKM-102:
Component SDI Kit (for audio)
Note
When the serial number of the BKM-101C you want to
connect is less than 2,010,000, an optional connecting
harness (part no. 1-900-230-35) will be required.
Serial Remote Interface Kit
By using the optional BKM-103 Serial Remote
Interface Kit, the monitor can be controlled from
personal computers via the RS-422A serial interface.
EIA 19-inch rack mount kit available
Use a suitable kit when rack mounting.
Europe
Any other area
ATTENTION – When the product is installed in
a rack:
a) Elevated operating ambient temperature
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of
the rack environment may be greater than room
ambient. Therefore, consideration should be
given to installing the equipment in an
environment compatible with the manufacturer's
maximum rated ambient temperature (Tmra).
b) Reduced air flow
Installation of the equipment in a rack should be
such that the amount of air flow required for
safe operation of the equipment is not
compromised.
c) Mechanical loading
Mounting of the equipment in the rack should
be such that a hazardous condition is not
achieved due to uneven mechanical loading.
d) Circuit overloading
Consideration should be given to the
connection of the equipment to the supply
circuit and the effect that overloading of circuits
might have on overcurrent protection and
supply wiring. Appropriate consideration of
equipment nameplate ratings should be used
when addressing this concern.
e) Reliable earthing
Reliable earthing of rack-mounted equipment
should be maintained. Particular attention
should be given to supply connections other
than direct connections to the branch circuit
(e.g., use of power strips).