Installation Procedure
All manuals and user guides at all-guides.com
1. Clean the area indicated on the topside of the Glove
2. Attach the Double-Sided tape to the Glove Box
3. Attach the Foam Tape to the SES ECU as shown.
- 6 -
SES ECU Preparation and Installation
Box Inner Cover.
Inner Cover as shown.
• Clean attachment surface using isopropyl alcohol and
cleaning towel.
• To achieve maximum bond strength of Tape, the
attachment surface temperature must be between
68°F-110°F (20°C-43°C) upon application.
• Verify that the Double-sided tape is firmly attached.
• Clean attachment surface using isopropyl alcohol and
cleaning towel.