Engine Run-Time Changing Procedure
1 Cycle ×3
1 Cycle
OPEN
CLOSE
All manuals and user guides at all-guides.com
1. Remove the Driver's Side Under Cover.
2. Press the "ENGINE START STOP" Button twice to
3. Connect the 1P SES Diagnostic Connectors.
4. Cycle the "ENGINE START STOP" Button from OFF
5. Open and close the Driver's Side Door to change
Answer-back
6. Turn the "ENGINE START STOP" Button to OFF.
7. Disconnect the 1P SES Diagnostic Connectors.
8. Secure the 1P SES Diagnostic Connectors using
- 34 -
• If registration of the Smart Engine Start ID is not
completed, the Smart Engine Start will not operate.
• The Engine Run-time settings must adhere to state,
provincial, and local laws and regulations.
switch ignition ON.
ACC
IG ON 3 times, and check the number of
answer-back.
* The number of answer-back (simultaneous Hazard Lights
flash and Horn sound) will correspond to the current Engine
Run-Time.
* 1 answer-back : 3 minutes Engine Run-time
* 2 answer-backs: 10 minutes Engine Run-time
* 3 answer-backs: 15 minutes Engine Run-time
・The initial Engine Run-Time setting is 15 minutes.
the Engine Run-time setting.
The Engine Run-time will change as follows depending
on the number of times the Driver's Side Door is
opened and closed (1 Cycle).
* 1 Cycle - 1 answer-back : 3 minutes Engine Run-time
* 2 Cycle - 2 answer-backs: 10 minutes Engine Run-time
* 3 Cycle - 3 answer-backs: 15 minutes Engine Run-time
* If you perform 4 Cycles or more, the Engine Run-time
setting and answer-back will continually repeat the above
1 to 3 pattern.
・Wait until the answer-back horn stops sounding for
setting to complete before opening the door.
Electrical Tape.