1.
Set the rotary switch to the position V
2.
Attach the pin-plug of the black test lead to the COM-jack and the
pin-plug of the red test lead to the V, Ω, Hz %-jack.
3.
Connect the black test prod to the negative pole and the red test prod to
the positive pole of the circuit to be tested.
4.
Once the reading stabilizes, read the value. If the polarity is twisted a
"Minus sign" is displayed. Use the HOLD function if the reading is difficult
to read.
DC current / AC Current measurement
Avoid current measurements with the 10A setting for more than 30 seconds.
This can damage the device and / or the test leads.
1.
For measurements up to 4000 mA set the rotary switch to the
mA-Position and attach the pin-plug of the red test lead to the mA-jack. For
measurements up to 10 A set the rotary switch to the A-Position and attach
the pin-plug of the red test lead to the A-jack.
2.
Connect the black test prod to the negative pole and the red test prod
to the positive pole of the circuit to be tested.
3.
Once the reading stabilizes, read the value. If the polarity is twisted a
"Minus sign" is displayed. Use the HOLD function if the reading is difficult to
read.
Resistance measurement
Before making any measurements, make sure the circuit is disconnected from
any power source and all capacitors are properly discharged!
1. Set the rotary switch to the position
Attach the pin-plug of the black test lead to the COM-jack and the
2.
pin-plug of the red test lead to the V, Ω, Hz %-jack.
Connect the black test prod to the negative pole and the red test
3.
prod to the positive pole of the circuit to be tested.
Once the reading stabilizes, read the value. If the polarity is twisted a
4.
"Minus sign" is displayed. Use the HOLD function if the reading is
difficult to read.
Continuity test
Before making any measurements, make sure the circuit is disconnected from
any power source and all capacitors are properly discharged!