2.8 Loose the two cap nuts and washers. Take the NVR-SWITCH and make these two blots into the two fixing holes of the
NVR-SWITCH. Lock the two cap nuts and washers.

3.0 Setting of Fence

By turning fence setting screws in or out as required, adjust fence segment stops to true 90° and 45°.
4.0 Connection to Power Mains
4.1 Single phase machines:
Check if voltage of power mains matches with voltage stated on the machine's type plate. Fit plug matching your local
standard outlet to power cord. This machine must be safety earthed. The yellow/green (green) lead is the earth conductor. A
220/240 V circuit must have a 13 amp fuse.
Fitted on a 110 V circuit a min. 20 amp time-lag circuit breaker is required. Extension cords must have a min. Cross-section of
2.5 mm
/12 AWG.
2
4.2 3-phase machines:
Check if voltage of power mains matches with voltage stated on the machine's type plate. Fit plug of your local standard to
power cord, this machine must be safety earthed, the yellow/green (green) lead is the earth conductor. Min. lead cross
section required is 1.5 mm
4.3 Direction of rotation on 3-phase machines:
Switch machine on briefly to check cutter-block direction of rotation. If necessary correct by interchanging two phase leads
(black or brown). Do not interchange the yellow/ green earth lead with the blue neutral lead. If in doubt leave job to a
qualified electrician.

5.0 Switch

The machine supplied with a no-volt release solenoid switch (magnetic switch). This feature prevents the machine from
starting up after a power failure.
/16 AWG. Protect circuit with 16 amp time-leg fuses.