ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
Description of control panel
Control panel for gear motor BK800S, powered by 230V
single-phase; frequency 50-60 Hz.
Designed and built entirety by CAME Cancelli automatici
S.p.A., in full compliance with current safety standards,
and with an IP54 protecting rating.
Housing in ABS is equipped with vents to provide internal
air circulation. Guaranteed 24 months, unless tampered
with.
Technical description motherboard
This control board is powered across terminals L1 and
L2, and is protected by fuse on the main power line 8A.
Control systems are powered by low voltage and protect-
ed with by a 2A fuse.
The total power consumption of 24 V accessories must
not exceed 20W.
Fixed operating time of 150 seconds.
Photocells can be connected to obtain:
- Re-opening during the closing cycle (2-C1);
- Re-closing during the opening cycle (2-CX, see dip 8-9);
- Partial stop, shutdown of moving gate, with activation of
an automatic closing cycle (2-CX, see dip 8-9);
- Total stop (1-2), shutdown of gate movement without
automatic closing; a pushbutton or radio remote control
must be actuated to resume movement;
Note: If an normally closed safety contact (2-C1, 2-CX, 1-
2) is opened, the LED (n°11) will flash to indicate this
fact;
- Obstacle presence detection. When the motor is stopped
(gate is closed, open or half-open after an emercency stop
command), the transmitter and the control pushbutton will
be deactivated if an obstacle is detected by one of the
safety devices (for example, the photocells);
- Safety test function. The control unit will now check the
safety system every time an opening or closing command
is given (see pag. 7).
Other functions
- Automatic closing: The automatic closing timer is auto-
matically activated at the end of the opening cycle. The
preset, adjustable automatic closing time is automatical-
ly interrupted by the activation of any safety system, and
is deactivated after a STOP command or in case of pow-
er failure;
- Partial opening. Opening of the gate to allow for foot
traffic; activated by connecting to terminals 2-3P and ad-
justed with the AP-PARZ. trimmer. With this function, the
automatic closing can vary in the following way:
1) Dip 12 set to ON: after a partial opening, the time for
automatic closing functions independently of the adjust-
ment of the TCA trimmer and of the position of Dip 1; it is
set at 8 seconds.
2) Dip 12 set to OFF: after a partial opening, the time for
automatic closing is adjustable only if Dip 1 is set to ON.
- Cycle lamp. The lamp which lights the manoeuvring zone:
it remains lit from the moment the doors begin to open
until they are completely closed (including the time re-
quired for the automatic closure). In case automatic clo-
sure is not enabled, the lamp remains lit only during move-
ment (E-EX);
IMPORTANT: Shut off the mains power before servicing the inside of the unit.
-2-
All manuals and user guides at all-guides.com
Safety
- Courtesy Light. A light that illuminates the manoeuvring
zone; after an opening command, the light remains on for
a fixed time of 5 minutes and 30 seconds (E-EX, see
page 8);
- "Operator present" function: Gate operates only when
the pushbutton is held down (the radio remote control
system is deactivated);
- Pre-flashing for 5 seconds, while the door is opening
and closing;
- Master function; the panel assumes all the command
functions when two paired motors are used (see page 13);
- Slave function; this panel is exclusively controlled by
the "MASTER" (see p. 13);
- Enabling functions of partial-stop or re-closure during
opening; normally-closed contact (2-CX), select one of
the two functions by setting dip, see selection of func-
tions;
Adjustments
- Trimmer AP.PARZ. = Partial opening: 1" to 14";
- Trimmer TCA = Automatic closing time: 1" to 150";