2. Operation and function
2.1 Push buttons
operating control lamp
backward (-)
(selection / adjustment mode)
2.2 System-Monitoring-Display
system monitoring display
channel display
tool bar
|
30
All manuals and user guides at all-guides.com
forward (+)
2
1
3
OK
The controller is operated via three push buttons below
the display.
Button 1 is used for scrolling forward through the indication
menu or to increase the adjustment values. Button 2 is used
for scrolling backward and reducing values. Button 3 is used
for selecting channels and confirming adjustments.
During normal operation, only the display channels are
shown.
Î Scroll through the display channels by pressing buttons
1 and 2
Accessing the adjustment channels:
Î Scroll down in the display menu and press button 1
for approx. 2 seconds after you have reached the last
display item.
When an adjustment value is shown on the display,
is indicated to the right of the channel name.
Î Press button 3 in order to access the adjustment
mode
starts flashing.
Î Adjust the value using buttons 1 and 2
Î Briefly press button 3,
adjusted value will be saved.
The system monitoring display consists of three blocks:
channel display, tool bar and system screen.
The channel display consists of 2 lines. The upper line is an
alpha-numeric 16-segment display (text display) for displaying
channel names and menu items. In the lower 7-segment
display, the channel values and the adjustment parameters
are displayed.
Temperatures are either indicated in °F or °C, whereas tem-
perature differences are indicated in K or °Ra respectively.
The additional symbols of the tool bar indicate the current
system status.
Status
relay 1 active
maximum store temperature excee-
ded
store emergency shutdown active
collector emergency shutdown active
collector cooling active
system cooling active
store cooling active
holiday cooling function activated
holiday cooling function active
collector minimum limitation active
antifreeze function activated
antifreeze function active
manual operation relay 1 ON
manual operation relay 1 OFF
sensor defective
permanently appears,the
standard flashing
+
+
+
+