Lighting Instructions
Norseman 200 Plus and Norseman 250
WARNING
Burn Hazard
■ Before lighting, ensure the manual main
burner valve is completely closed. See Fig. 9
■ Failure to do so will result in the main burner
igniting at full heat output.
■ Serious injury or death due to burns may
occur.
1. Slowly open the propane gas container valve.
(This prevents lockup of the excess fl ow check valve
internal to the regulator's POL fi tting.)
2. Norseman 200 Plus:
Fully depress the button on the pilot safety control valve
while pushing the igniter button.
Norseman 250:
Apply a fl ame to the pilot assembly. Then depress the
button on the safety control valve to light the pilot.
■ On new installations it may take a short time for gas to
purge out any air before the pilot lights and stays lit.
3. Once the pilot fl ame is lit, keep the pilot button de-
pressed for about 30 seconds to allow the thermocouple
to warm up.
4. Release the safety control valve button.
5. Slowly open the manual main burner valve located
between the pilot safety control and burner.
FIG. 9
PILOT ASSEMBLY
Vertical Convection Heaters
Shut-Down Instructions
A. To properly shut heater down after normal use, or
-- Close the manual main burner valve on heater.
B. To properly shut heater down for storage, or when
1. Close propane gas supply container valve. Allow
2. Close manual main burner valve on heater.
3. Disconnect the heater from its gas supply.
MAIN BURNER VALVE
PILOT BUTTON
IGNITER BUTTON
Owner's Manual • Workman & Norseman
when further use is anticipated:
The pilot will stay lit.
further use is not anticipated:
heater to burn off remaining gas in its hose.