Télécharger Imprimer la page

Elvox ES82 Guide De Connexion page 21

Publicité

Les langues disponibles

Les langues disponibles

If DIP21 = ON the device functions in Open-Close mode. In this case:
APARTMENT BLOCK AUTOMATIC, SUPER AUTOMATIC, AUTOMATIC:
an OPEN pulse always results in opening and a CLOSE pulse in closing; once open, the gate remains paused for the specified pause
time. A CLOSE pulse during the pause sends a closing command. The courtesy function, if provided, remains active.
SEMI-AUTOMATIC, STEP OPERATION:
an OPEN pulse always results in opening and a CLOSE pulse in closing.
INPUTS, OUTPUTS AND OPERATIONS
Inputs
N. 16 COM
N. 17 AP/CH
N. 20 STOP
N. 18 APED
N.19 COM
N. 21 FOTO
N. 22 STPA
N. 13 FCAP
N. 14 COM
N. 15 FCCH
Outputs
N. 9 (-)
2CAN
N. 11 (+)
N. 10 (-)
AUX
N. 11 (+)
(Pilot lamp)
N. 11 (+)
24V
N. 12 (-)
N. 4
LAMP
N. 5
Operating
OBSTACLE WHEN CLOSING The gate immediately reverses its movement.
OBSTACLE WHEN OPENING The gate immediately reverses its movement for 1.5 sec and comes to a stop.
DIP SWITCH
DSW1
dip 1
Release / engagement stroke
dip 2
dip 3
dip 4
STPA In (partial stop on opening)
dip 8
DSW2
dip 21
Open-Close mode
dip 22
All manuals and user guides at all-guides.com
PROGRAMMING
Description
Common for commands
Makes the leaf open/close. See operating modes. NA contact.
Stops all manoeuvres and until active it disables all manoeuvres. NC contact.
Pedestrian opening if the gate is closed. NA contact. Makes the gate close if the gate is open or stop-
ped.
Common for safety devices
Photocell, NC contact, if the gate is closing it reverses the movement and until engaged it prevents the
gate from closing.
Photocell on opening, stops all manoeuvres and until engaged it disables all manoeuvres. When relea-
sed: gate opens. NC contact.
Gate opening limit
Common limit
Gate closing limit
Description
Second channel output
if dip 3 = OFF it activates on receipt of the radio control.
If dip 3 = ON connect the TX photocells for test .
24Vdc output for remote signalling of gate status:
If Dip 22 = OFF: off when the gate is closed, otherwise on.
If Dip 22 = ON: flashing during movement
24Vdc output. Photocells power supply.
Non-intermittent output for flashing light with card
Description
Function
Pre-flashing
2CAN Out
Photocell test
Function
AUX out
ON
Enabled
Enabled
Power sup. TX Photocells (test)
Resistive Edge
Enabled
ON
Enabled
Flashing beacon
21/36
OFF
Disabled
Disabled
Second radio control channel
Photocell 2
Disabled
OFF
Disabled
Warning light