GB
PROGRAMMING
During the learning procedure, in addition to memorising deceleration spaces and pedestrian opening travel, the system detects any en-
coder position detectors present.
4.1 Learning procedure for sliding gates
-
Close the gate fully
-
Press and hold learning pushbutton P1 for at least 3 seconds
-
The PROG LED begins to flash
-
Release pushbutton P1
-
Press APCH: the gate opens at normal speed
-
When you want the gate to move more slowly, press APCH
-
The slow speed phase begins
-
The gate then continues to move until it reaches its opening limit
-
Press APCH: the gate closes at normal speed
-
When you want the gate to move more slowly, press APCH
-
The slow speed phase begins
-
The gate then continues to move until it reaches its closing limit
-
Press APCH: the gate opens at normal speed
-
To set the partial pedestrian opening point, press APCH
-
Press APCH: the gate closes at normal speed
-
The gate then continues to move until it reaches its closing limit
-
Wait for the PROG LED to switch off
-
The learning procedure is complete.
OPERATING MODES
Select an operating mode by means of DSW1 dip switches 5, 6 and 7 referring to the table below (after each mode change it is necessary
to jumper the JR1 RESET contacts for a few seconds so that the change can take effect):
dip 5 dip 6 dip 7
OFF
OFF
OFF
Condominium automatic
OFF
OFF
ON
Condominium automatic + courtesy (*)
OFF
ON
OFF
Super automatic
OFF
ON
ON
Super automatic + courtesy (*)
ON
ON
OFF
Automatic
ON
ON
ON
Automatic + comfort (*)
ON
OFF
OFF
Semi automatic
ON
OFF
ON
Step by step
(*) The courtesy function enables the gate to be closed 5 seconds after the photocells have received a pulse, regardless of the timing of
the pause setting.
CONDOMINIUM AUTOMATIC:
Pressing START when the gate is closed makes it open. Pressing START while the gate is opening has no effect. Once open, the gate re-
mains paused for the set pause time. Pressing START during the pause restarts the time counter from zero. Pressing START while the gate
is closing makes it open again.
SUPER AUTOMATIC:
Pressing START when the gate is closed makes it open. Pressing START while the gate is opening stops the gate; pressing START a se-
cond time makes it close again. Once open, the gate remains paused for the set pause time. Pressing START during the pause closes the
gate. Pressing START while the gate is closing makes it open again.
AUTOMATIC:
Pressing START when the gate is closed makes it open. Pressing START when the gate is opening has no effect. Once open, the gate re-
mains paused for the set pause time. Pressing START during the pause closes the gate. Pressing START while the gate is closing makes
it open again.
SEMI AUTOMATIC:
Pressing START when the gate is closed makes it open. Pressing START while the gate is opening stops the gate; pressing START a se-
cond time makes it close again. The gate remains open until START is pressed, which makes it close. Pressing START while the gate is
closing makes it open again.
STEP BY STEP:
Pressing START when the gate is closed makes it open. Pressing START while the gate is opening stops the gate; pressing START a se-
cond time makes it close again. The gate remains open until START is pressed, which makes it close. When the gate is closing, pressing
START stops the gate and pressing START a second time makes it open again.
All manuals and user guides at all-guides.com
GENERAL CHARACTERISTICS
DWS1 – operating mode
20/36
Mode
OPEN
(Automatic closing enabled)
OPEN-STOP-CLOSE-OPEN
(Automatic closing enabled)
OPEN-CLOSE-OPEN
(Automatic closing enabled)
OPEN-STOP-CLOSE-OPEN
OPEN-STOP-CLOSE-STOP-OPEN