Télécharger Imprimer la page

RIB TOUCH Mode D'emploi page 8

Barre palpeuse mécanique, dispositif de protection pour organes en mouvement

Publicité

Les langues disponibles

Les langues disponibles

G
B
TECHNICAL DATA / INSTALLATION
TOUCH is a device for guaranteeing protection of persons and property from impact or
entrapment with moving mechanical automatic gate or door parts.
The obstacle is detected along the entire length of the device in axial and perpendicular
movement.
The device has been certified EN 13849-2 (2013) - PL "b" Category 3.
The device may not be modified in any manner.
The device is supplied with a jumper inserted to have an NC contact output (normally
closed).
By simply removing the jumper, the contact output will become resistive 8.2 Kohm.
TYPE OF ITEMS FOR ASSEMBLY
TOU0001
TOU0002
TOU0003
TOU0004
TOU0011
ASSEMBLY INSTRUCTIONS
The device requires installation by skilled, expert and qualified personnel.
TOUCH can either be mounted on the mobile or fixed part of the gate or door. In either case
the purpose of the device is to prevent damage or injury from crushing or impact.
Positioning of the device is shown in examples in Pic. 1.
* If you install TOUCH with gate leaves having a travelling speed higher than 0.25m/s, the safety norm cannot be abide by.
Rubber profile available
in packages of n° 2 items
7 m length
Aluminium profile available
in strips from 2 m
Steel cable
Upper group
Upper cover
Screws for upper cover
Accessories for assembling
Aluminium profile
8
TECHNICAL CHARACTERISTICS
Electric contact capacity
Operating temperature
Rubber profile stroke to the electric contact intervention
Rubber profile stroke from intervention (extra-stroke)
Contact opening intervention time
Maximum deformation recuperation time
Maximum applicable force of device
Maximum speed of device in movement
Protection
TOU0007
TOU0008
TOU0008
TOU0010
TOUCH must be fixed to the aluminium rail, with its leading rubber edge facing in the
direction of any eventual impact as indicated in Pic. 1.
0,5 A - 24 V ac/dc
min. -20°C, max 50°C
max. 15 mm
min. 40 mm
max. 0,1 sec.
max. 0,5 sec.
max. 1 KN
max. 0,25 m/sec.*
IP44
Steel flat connector
Lower group
Lower cover
Screws for lower cover
Lower cover with fastening
screws
Upper cover with fastening
screws

Publicité