ENGLISH
ENERGY SAVING FUNCTIONS
This monitor is equipped with power management
functions according to GEA (formerly E2000), EPA, and
VESA DPMS standard. If your computer is using a VESA
DPMS-compatible graphics adapter or appropriate
software, energy consumption can be automatically
reduced when your monitor is idle. When the monitor is
in power saving mode, the color of the status LED (see
VESAs
Video
Mode
On
aktive
Stand-by
blanked
Suspend
blanked
Off
blanked
This monitor is ENERGY STAR ® -compatible. MAXDATA is an ENERGY STAR ® partner and guarantees that this device
complies with the ENERGY STAR ® guidelines for optimizing power consumption.
TECHNICAL SPECIFICATIONS
Picture tube
Input signal
Display colors
Synchronization
Pixel clock
Resolution
Misconvergence
Power supply
Power consumption
Dimensions
Weight
Operating environment
PIN ASSIGNMENT
Pin
Assignment
Pin
1
Red
9
2
Green
10
3
Blue
11
4
Ground
12
5
13
6
Red return
14
7
Green return
15
8
Blue return
18 - Belinea 10 80 80
All manuals and user guides at all-guides.com
H-sync
V-sync
yes
yes
typical 124 watts
no
yes
yes
no
no
no
22 inches diagonal size (50.8 cm visible),
0.24 mm stripe mask, antistatic/antireflective coating
low emissions according to MPR II and TCO 99,
phosphorus type P22
analog 0.7 Vpp / 75 Ohm, positive
Synchronization: separate, TTL level
Horizontal synchronization: positive/negative
Vertical synchronization: positive/negative
Analog input, unlimited colors
30 - 121 kHz horizontal
50 - 160 Hz vertical
320 MHz
max. 2048 x 1536 pixels
center: max. 0.15mm; main area: max 0.30mm; edge: max. 0.35mm
90 - 264 VAC, 47/63 Hz
typical 124 W (Standby: < 3 W, Off-Status: < 3 W); Power saving functions GEA
(formerly E2000), EPA and VESA-DPMS certified
501 mm (width) x 502.3 mm (height) x 476.9 mm (depth); (monitor only)
30.0 kg (monitor only)
Temperature: 0 to 40 °C
Rel. humidity 20 to 80 % (without condensation)
Assignment
+ 5V DDC
Ground
Ground
SDA
Hor. synch.
Vert. synch.
SCL
R
in figure 4) will turn yellow. The monitor will
automatically switch back on when you use the
keyboard, mouse or another input device.
The following table illustrates power consumption
values and display indications for this automatic power
saving feature:
Power
Power
Used
Saving (%)
0
< 3 watts
97
< 3 watts
97
< 3 watts
97
15 pin D-Sub connector
LED
color
green
yellow
yellow
yellow