5.8.5 ADDING VENT SECTIONS
Add chimney sections, according to the manufacturers installation instructions. The chimney must extend at
EN
least, 3 feet (0.9m) above its point of contact with the roof and at least 2 feet (0.6m) higher than any wall, roof,
building or obstacle within 10 feet (3.1m) horizontally.
LESS THAN
10 FEET
(3.1m)
2 FT (0.6m)
2 FT (0.6m) MIN
3 FT
RIDGE
MIN
3 FT
(0.9m)
10 FT (3.1m)
(0.9m)
MIN
TO NEAREST
MIN
ROOFLINE
LESS THAN
10 FEET
(3.1m)
10 FT
(3.1m) OR
MORE
3 FT
2 FT (0.6m)
3 FT
(0.9m)
MIN
(0.9m)
MIN
MIN
FLAT ROOF
WALL
59.1B
W415-0791 / D / 10.21.13