INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
MEETS THE 2015 U.S ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) CRIB WOOD EMISSION LIMITS FOR WOOD
STOVES SOLD AFTER MAY 15, 2015, 40 C.F. R. PART 60. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO
C1450
PEDESTAL MODEL
SAFETY INFORMATION
WARNING
!
If the information in these instructions is not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or death. Improper installation, adjustment,
alteration, service or maintenance can cause injury or
property damage, bodily injury or even death. Please read
entire manual before you install and use your appliance.
This appliance has not been tested with an unvented gas log
set. To reduce risk of fi re or injury, do not install an unvented
gas log set into the appliance.
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed too
close can catch fi re.
- Children and pets must be kept from touching the appliance when it
is hot.
- The chimney must be sound and free of cracks. Before installing
this unit, contact the local building or fi re authority and follow their
guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- At least 14 square inches (90.3 square centimeters) of outside air must
be admitted to the room or directly to the unit through a 4" (101.6mm)
diameter pipe.
- This appliance is designed to burn natural wood only. Higher
effi ciencies and lower emissions generally result when burning air
dried seasoned hardwoods, as compared to softwoods or to green or
freshly cut hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine
oil, etc.
- Do not burn treated wood, coal, charcoal, colored paper, cardboard,
solvents or garbage.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C).
Attempts to achieve heat output rates that exceed design
specifi cations can result in steel distortion and damage.
Phone (705)721-1212 • Fax (705)722-6031 • www.continentalfi replaces.com • ask@continentalfi re.on.ca
$10.00
OPERATING INSTRUCTIONS
STANDARDS: CSA B366.2, ULC S627, UL 1482.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
WARNING
!
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.30B
W415-1582/10.02.15
EN
FR
PG.
37

Publicité

loading

Sommaire des Matières pour Continental Fireplaces C1450

  • Page 1 MEETS THE 2015 U.S ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) CRIB WOOD EMISSION LIMITS FOR WOOD STOVES SOLD AFTER MAY 15, 2015, 40 C.F. R. PART 60. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2, ULC S627, UL 1482. C1450 PEDESTAL MODEL SAFETY INFORMATION...
  • Page 2 TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS SPECIFICATIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION PRE-INSTALLATION PREPARATION APPLIANCE PLACEMENT CLEARANCE TO COMBUSTIBLES FLOOR PROTECTION OUTSIDE AIR 3.4.1 OUTSIDE AIR - MOBILE HOME MOBILE HOME INSTALLATION CHIMNEY 4.1.1 CHIMNEY CONNECTION 4.1.2 ADDING SECTIONS 4.1.3 TYPICAL THROUGH THE CEILING...
  • Page 3 1.0 INSTALLATION OVERVIEW Rating plate, see “RATING PLATE INFORMATION” section. Door, see “DOOR REMOVAL / INSTALLATION” section. Blower, see “OPTIONAL BLOWER KIT INSTALLATION” section. Draft, see “AIR CONTROL” section. Handle, see “DOOR AND HANDLE INSTALLATION” section. Brick and Baffles, see “BRICK AND BAFFLES INSTALLATION”...
  • Page 4 2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5 DIMENSIONS 6” (152.4 mm) DIA. SPECIFICATIONS SPECIFICATIONS Ref. C1450 WIDTH 25 1/2” (647.7 mm) DEPTH 27” (685.8 mm) FLUE CENTER LINE TO REAR 7 1/2” (190.5 mm) FLUE CENTER LINE TO SIDE 12 3/4” (323.9 mm) HEIGHT 33 1/4” (844.6 mm) CHAMBER (D.W.H)
  • Page 6 GENERAL INSTRUCTIONS WARNING ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN THE UNITED STATES.
  • Page 7 GENERAL INFORMATION WARNING DO NOT OPERATE THIS APPLIANCE WITHOUT THE PEDESTAL INSTALLED. Your appliance has been specifi cally designed over many months of research to meet the 1990 U.S.A. EPA particu- late emission standards and have been extensively tested in Canadian and American laboratories. This system is the most effi...
  • Page 8 RATING PLATE INFORMATION For rating plate location, see “IN- LISTED SOLID FUEL BURNING SPACE HEATER / POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉ TESTED TO: / TESTÉ SELON : UL1482 / ULC S627 STALLATION OVERVIEW” section. MODEL / MODÈLE - EPA 1400 9700539 (WSL) 1450 1400C...
  • Page 9 DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (2.1m) (CEILING OF ENCLOSURE TO APPLIANCE BOTTOM, EXCLUDING HEARTH HEIGHT). BACK WALL BACK WALL PARALLEL & CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR C1450 C1450 SIDEWALL (A) 12” (304.8 mm) 10” (254 mm) SIDEWALL TO FLUE (B) 21” (533.4 mm) 19”...
  • Page 10 FLOOR PROTECTION EMBER PROTECTOR: This appliance must be installed on a non-combustible protector that extends to the front, sides and back of the appliance as per the minimum requirements below. NOTE: Ember protection is required for spark and ash shielding, not for limiting fl oor temperatures from the radiant heat of the appliance.
  • Page 11 INSTALL ACCORDING TO 24 CFR, PART 3280 (HUD). USE A CHIMNEY CERTIFIED FOR WOOD BURNING UL 103 S629, TYPE HT (2100°F). RAIN CAP Model C1450 is approved for installation in mobile REMOVE TO homes in the United States only. ALLOW FOR...
  • Page 12 4.0 INSTALLATION WARNING WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION. CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS NEEDED TO INSTALL THE APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
  • Page 13 CHIMNEY WARNING NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE. THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO COMBUSTIBLE CHASE MATERIALS TO CAUSE FIRE. DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE. TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDING THE PROVISIONS OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE.
  • Page 14 4.1.1 CHIMNEY CONNECTION Your chimney connector and chimney must have the same diameter as the appliance’s exhaust fl ue outlet. The appliance pipe must be made of aluminized or cold roll steel with a minimum 24 gauge thickness. It is strictly forbidden to use galvanized steel.
  • Page 15 4.1.2 ADDING SECTIONS Add chimney sections, according to the manufacturers installation instructions. The chimney must extend at least, 3 feet (1m) above its point of contact with the roof and at least 2 feet (0.6m) higher than any wall, roof, building or obstacle within 10 feet (3m) horizontally.
  • Page 16 4.1.3 TYPICAL THROUGH THE CEILING Move the stove into position with the fl ue centered, midpoint between two joists to prevent having to cut them. Use a plumb bob to line up the center. Cut and frame an opening in the ceiling to provide a 2” (50.8mm) clearance between the outside of the chimney and any combustible material.
  • Page 17 4.1.4 TYPICAL THROUGH THE WALL If possible, design the installation so that the connector does not pass through a combustible wall. If during your installation you must pass through a combustible wall, check with your building inspector before you begin. Also check with the chimney connector manufacturer for any specifi c requirements. Consult with your dealer regarding special connection components available for use for wall pass-throughs.
  • Page 18 4.1.5 TYPICAL EXISTING MASONRY You can also install your appliance using your existing masonry chimney. To do so, follow the guidelines below. Use a factory-built thimble, or construct your own brick thimble. If you are using a masonry chimney, it is important that it be built in compliance with the specifi...
  • Page 19 5.0 FINISHING DOOR REMOVAL / INSTALLATION Pivot the door open and lift up to clear the bushings. Do not pivot the door any further than necessary. Carefully set the door aside and pull the pins out from the door bushings. Repeat in reverse order to install the door.
  • Page 20 BRICKS AND BAFFLE INSTALLATION WARNING OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERATURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING ENCLOSURE. With appliance and chimney installation completed, move the bricks into place for your appliance as illustrated.
  • Page 21 4 1/2” x 9” (114mm x 229mm) 4 1/2” x 9” (Notched) (114mm x 229mm) 3” x 9” (Molded) (6mm x 229mm) 2 1/4” x 9” (57mm x 229mm) 4 1/2” x 4 1/2” (114mm x 144mm) 2 1/4” x 6 1/8” (64mm x 121mm) 3”...
  • Page 22 6.0 OPTIONAL KIT INSTALLATIONS OPTIONAL BLOWER KIT INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 23 7.0 OPERATION WARNING ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED EXCEPT DURING START UP AND RE-FUELING. ALWAYS WEAR GLOVES TO PREVENT INJURY. DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED AS UNSTABLE WOOD COULD FALL OUT OF THE FIRE CHAMBER CREATING A FIRE HAZARD TO YOUR HOME.
  • Page 24 and the chimney becomes heated and provides a good draft. At this point, the roaring fi re that you see when the door is opened is wastefully drawing heated room air up the chimney -- certainly not desirable. Always operate with the door fully closed once the medium sized logs have caught fi re. You can now add larger pieces of wood and operate the appliance normally.
  • Page 25 AIR CONTROL Draft is the force which moves air from the fi rebox up through the ASH LIP chimney. The amount of draft in your chimney depends on the length and diameter of chimney, local geography, nearby obstruc- tions and other factors including the amount of heat generated by the fi...
  • Page 26 8.0 MAINTENANCE WARNING TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is established.
  • Page 27 RUNAWAY OR CHIMNEY FIRE WARNING A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRES ARE NOT COVERED BY THE LIFETIME LIMITED WARRANTY. Runaway fi res can be the result of three major factors: •...
  • Page 28 CHIMNEY CLEANING Both the chimney and the appliance must be inspected and cleaned if necessary at least once a year. For serious wood burners, chimney cleaning must be done as needed to avoid chimney fi res; the venting systems for controlled combustion appliances may need cleaning as often as once a month. These rates, however, depend on the burning habits of the individual operating the appliance.
  • Page 29 SECONDARY AIR MANIFOLD REPLACEMENT At the end of each burning season inspect the secondary air manifold for warping or deterioration. Replace if necessary. At this time also check that the door gasket is not worn, frayed or loose. Replace with 1/2" (13mm) high density fi...
  • Page 30 CARE OF GLASS If the glass is not kept clean permanent discolouration and / or WARNING blemishes may result. Normally a hot fi re will clean the glass. The most common reasons for dirty glass include: not using HOT GLASS WILL suffi...
  • Page 31 WOOD WARNING THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY. DO NOT BURN TREATED WOOD, COAL, CHARCOAL, COLOURED PAPER, CARDBOARD, SOLVENTS OR GARBAGE. THIS APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THE APPLIANCE.
  • Page 32 9.0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. WARNING FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS When ordering replacement parts always give the following information:...
  • Page 33 10.0 TROUBLESHOOTING WARNING TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. WHEN CHECKING CONNECTIONS, INSTALLING JUMPER WIRES (FOR TEST PURPOSES ONLY) OR REPLACING COMPONENTS, UNPLUG HEATER FROM THE RECEPTACLE TO PREVENT ELECTRICAL SHOCK OR DAMAGE TO THE COMPONENT.
  • Page 34 11.0 WARRANTY CONTINENTAL® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete appliance is again thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from CONTINENTAL®. CONTINENTAL®...
  • Page 35 12.0 SERVICE HISTORY 43.1 W415-1582/10.02.15...
  • Page 36 W415-1582/10.02.15...
  • Page 37 D’ÉMISSIONS DE BOIS DE VALEUR STANDARD POUR LES POÊLES À BOIS VENDUS APRÈS LE 15 MAI 2015, 40 C.F. R. SECTION 60. CES POÊLES ONT ÉTÉTESTÉS ET HOMOLOGUÉS PAR INTERTEK TESTING SERVICES SELON LES NORMES CSA B366.2, ULC S627, UL 1482. C1450 MODÈLES SUR PIÉDESTAL CONSIGNES DE SÉCURITÉ...
  • Page 38 TABLE DES MATIÈRES VUE D’ENSEMBLE DE L’INSTALLATION INTRODUCTION DIMENSIONS SPÉCIFICATIONS INSTRUCTIONS GÉNÉRALES INFORMATION GÉNÉRALE INFORMATION SUR LA PLAQUE D’HOMOLOGATION PRÉPARATION AVANT L’INSTALLATION INSTALLATION DE L’APPAREIL DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES PROTECTION DU PLANCHER AIR EXTÉRIEUR 3.4.1 PRISE D’AIR EXTÉRIEUR - MAISON MOBILE MAISON MOBILE INSTALLATION CHEMINÉE...
  • Page 39 1.0 VUE D’ENSEMBLE DE L’INSTALLATION Plaque d’homologation, voir la section « INFORMATION SUR LA PLAQUE D'HOMOLOGATION ». Porte, voir la section « ENLÈVEMENT ET INSTALLATION DE LA PORTE ». Soufflerie, voir la section « INSTALLATION DE LA SOUFFLERIE OPTIONNELLE ». Retour d’air, voir la section «...
  • Page 40 2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • TOUTE MODIFICATION APPORTÉE À CET APPAREIL OU AUX CONTRÔLES PEUT ÊTRE DANGEREUX ET EST INTERDIT. • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures.
  • Page 41 DIMENSIONS 6” (152.4 mm) DIA. SPÉCIFICATIONS SPÉCIFICATIONS Réf. C1450 LARGEUR 25 1/2” (647.7 mm) PROFONDEUR 27” (685.8 mm) CENTRE DE LA BUSE JUSQU’À L’ARRIÈRE 7 1/2” (190.5 mm) CENTRE DE LA BUSE JUSQU’AUX CÔTÉS 12 3/4” (323.9 mm) HAUTEUR 33 1/4” (844.6 mm) CHAMBRE DE COMBUSTION (P.L.H.)
  • Page 42 INSTRUCTIONS GÉNÉRALES AVERTISSEMENT CET APPAREIL DOIT ÊTRE RACCORDÉ ÉLECTRIQUEMENT PAR UN ÉLECTRICIEN QUALIFIÉ CONFORMÉMENT AUX CODES LOCAUX. EN L’ABSENCE DE CODES LOCAUX, UTILISEZ LA VERSION COURANTE DU CODE CANADIEN DE L'ÉLECTRICITÉ CSA C22.1 (AU CANADA) OU LE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 AUX ÉTATS-UNIS. CET APPAREIL N’A PAS ÉTÉ...
  • Page 43 INFORMATION GÉNÉRALE AVERTISSEMENT NE PAS UTILISER CET APPAREIL SANS QUE LE PIÉDESTAL SOIT INSTALLÉ. Votre appareil a été conçu afi n de répondre spécifi quement aux exigences des normes d’émissions de particules de l’E.P.A. américaine de 1990 et a subi un nombre considérable de tests dans des laboratoires canadiens et américains.
  • Page 44 INFORMATION SUR LA PLAQUE D’HOMOLOGATION Pour l’emplacement de la LISTED SOLID FUEL BURNING SPACE HEATER / POÊLE À COMBUSTIBLE SOLIDE plaque d’homologation, voir la HOMOLOGUÉ TESTED TO: / TESTÉ SELON : UL1482 / ULC S627 section « VUE D’ENSEMBLE MODEL / MODÈLE - EPA 1400 DE L’INSTALLATION ».
  • Page 45 MUR ARRIÈRE PARALLÈLE ET EN COIN CONDUIT DE RACCORDEMENT CONDUIT DE RACCORDEMENT À PAROI SIMPLE À PAROI DOUBLE C1450 C1450 MUR DE CÔTÉ (A) 12” (304.8 mm) 10” (254 mm) MUR DE CÔTÉ À LA BUSE (B) 21” (533.4 mm) 19”...
  • Page 46 PROTECTION DU PLANCHER PROTECTEUR DES BRAISES: L’appareil doit être installé sur un protecteur thermique incombustible se prolongeant sur le devant, les côtés et l’arrière de l’appareil selon les exigences minimales ci-dessous. NOTE : Une protection de plancher est requise pour protéger des étincelles et de la cendre, mais non pour limiter la température du plancher de la chaleur rayonnante de l’appareil.
  • Page 47 INSTALLEZ CONFORMÉMENT À LA NORME 24 CFR, PART 3280 (HUD). UTILISEZ UNE CHEMINÉE DE TYPE UL 103HT OU ULC S-629 (2100 °F) CERTIFIÉE POUR LA COMBUSTION DU BOIS. Les modèles C1450 sont homologués pour CHAPEAU installation dans les maisons mobiles aux États-Unis RETIREZ LORSQUE uniquement.
  • Page 48 4.0 INSTALLATION AVERTISSEMENT PORTEZ DES GANTS ET DES LUNETTES DE PROTECTION. SUIVEZ ATTENTIVEMENT LES INSTRUCTIONS POUR L'ASSEMBLAGE DE LA CHEMINÉE ET DES AUTRES COMPOSANTS NÉCESSAIRES À L'INSTALLATION DE L’APPAREIL. TOUTE OMISSION POURRAIT CAUSER UN INCENDIE, PARTICULIÈREMENT SI DES MATÉRIAUX COMBUSTIBLES SONT TROP PRÈS DE L’APPAREIL OU DE LA CHEMINÉE ET QUE DES OUVERTURES D'AIR SONT BLOQUÉES, EMPÊCHANT LA LIBRE CIRCULATION DE L'AIR DE REFROIDISSEMENT.
  • Page 49 CHEMINÉE AVERTISSEMENT NE JAMAIS INSTALLER UN CONDUIT DE RACCORDEMENT À PAROI SIMPLE DANS UNE ENCEINTE. LES TEMPÉRATURES PLUS ÉLEVÉES DE CE CONDUIT PEUVENT IRRADIER SUFFISAMMENT DE CHALEUR AUX MATÉRIAUX COMBUSTIBLES POUR CAUSER UN INCENDIE. NE RACCORDEZ PAS CET APPAREIL AU CONDUIT D’UNE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
  • Page 50 4.1.1 INSTALLATION DE LA CHEMINÉE Votre conduit de raccordement et votre cheminée doivent avoir le même diamètre que le tuyau d’échappement de l’appareil. Le tuyau de l’appareil doit être en acier aluminié ou en acier laminé à froid d’une épaisseur mini- male de calibre 24.
  • Page 51 4.1.2 AJOUT DE SECTIONS Ajoutez des sections de cheminée, selon les instructions d’installation des manufacturiers. La cheminée doit dépasser le toit d’au moins 3’ (0,9m) de son point de contact avec la toiture, et 2’ (0,6m) de tout mur, toit ou édifi...
  • Page 52 4.1.3 TYPIQUE À TRAVERS LE PLAFOND Mettez l’appareil en place. Repérez le centre de la buse de façon à ne pas avoir à couper les solives. Utilisez un fi l à plomb pour aligner le centre de la buse. Découpez et charpentez une ouverture dans le plafond de façon à fournir un dégagement de 2”...
  • Page 53 4.1.4 INSTALLATION TYPIQUE À TRAVERS UN MUR Si possible, l’installation des conduits de raccordement ne doit pas passer à travers un mur combustible. S’il faut absolument passer à travers un mur combustible, consultez votre inspecteur en bâtiment avant de procéder. Consultez aussi le fabricant des conduits de raccordement pour connaître toutes les exigences particulières.
  • Page 54 4.1.5 INSTALLATION TYPIQUE DANS UNE CHEMINÉE DE MAÇONNERIE EXISTANTE Vous pouvez aussi installer votre appareil en utilisant votre cheminée de maçonnerie existante. Pour ce faire, suivez les directives suivantes. Nous vous conseillons d’installer un coupe-feu préfabriqué ou d’en construire un. Si vous utilisez une cheminée en maçonnerie, vous devez vous assurer qu’elle réponde aux CHEVRON...
  • Page 55 5.0 FINITIONS ENLÈVEMENT ET INSTALLATION DE LA PORTE Pivotez la porte pour l’ouvrir et soulevez-la pour dégager les bagues. Ne pivotez pas la porte plus que nécessaire. Mettez soigneusement la porte de côté et retirez les tiges des bagues de la porte. Suivez les instructions en sens inverse pour installer la porte.
  • Page 56 INSTALLATION DES BRIQUES ET DES DÉFLECTEURS EN FIBRE AVERTISSEMENT L'UTILISATION DE L’APPAREIL SANS LES DÉFLECTEURS PEUT CAUSER DES TEMPÉRATURES EXCESSIVES QUI POURRAIENT ENDOMMAGER L’APPAREIL, LA CHEMINÉE ET L'ENCEINTE. Une fois l’installation de l’appareil et du tuyau de raccordement complétée, mettez les briques en place en procédant tel qu’illustré...
  • Page 57 4 1/2” x 9” (114mm x 229mm) 4 1/2” x 9” (Entaillée) (114mm x 229mm) 3” x 9” (Moulée) (6mm x 229mm) 2 1/4” x 9” (57mm x 229mm) 4 1/2” x 4 1/2” (114mm x 144mm) 2 1/4” x 6 1/8” (64mm x 121mm) 3”...
  • Page 58 6.0 INSTALLATION DES ENSEMBLES OPTIONNELS INSTALLATION DE LA SOUFFLERIE OPTIONNELLE AVERTISSEMENT RISQUE D’INCENDIE ET DE CHOC ÉLECTRIQUE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. N’UTILISEZ QUE LES ACCESSOIRES OPTIONNELS ET LES PIÈCES DE RECHANGE APPROUVÉS PAR WOLF STEEL POUR CET APPAREIL.
  • Page 59 7.0 FONCTIONNEMENT AVERTISSEMENT FAITES TOUJOURS FONCTIONNER CET APPAREIL AVEC LA PORTE FERMÉE ET VERROUILLÉE SAUF DURANT L'ALLUMAGE ET LE RAVITAILLEMENT. PORTEZ TOUJOURS DES GANTS POUR PRÉVENIR LES BLESSURES. NE LAISSEZ PAS L’APPAREIL SANS SUPERVISION LORSQUE LES PORTES SONT DÉVERROUILLÉES. DU BOIS INSTABLE POURRAIT TOMBER HORS DE LA CHAMBRE DE COMBUSTION ET CRÉER UN RISQUE D'INCENDIE.
  • Page 60 Une fois que la porte est fermée, vous observerez un changement dans le comportement des fl ammes. Elles deviendront plus petites et plus paresseuses parce que le volume d’oxygène qui entre dans la chambre de combustion est moindre. Cependant, les fl ammes sont plus effi caces. Elles continueront d’être paresseuses, mais redeviendront plus grandes dès que les briques réfractaires auront été...
  • Page 61 CONTRÔLE D’AIR Le tirage est la force qui déplace l’air de la chambre de combustion vers le haut, dans la cheminée. La force de PARE-CENDRES tirage de votre cheminée dépend de sa hauteur et de son diamètre, de la géographie locale, des obstructions avoisinantes et d’autres facteurs, incluant la quantité...
  • Page 62 8.0 ENTRETIEN AVERTISSEMENT COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. L’APPAREIL PEUT ÊTRE CHAUD. N’EFFECTUEZ AUCUN ENTRETIEN JUSQU’À CE QUE L’APPAREIL SOIT REFROIDI. N’UTILISEZ PAS DE NETTOYANTS ABRASIFS. Afi n de prévenir les accumulations de suie et de créosote, vérifi ez votre cheminée et le conduit de raccorde- ment toutes les semaines jusqu’à...
  • Page 63 FORMATION ET ENLÈVEMENT DE LA CRÉOSOTE Lorsque le bois brûle lentement, il produit du goudron et autres vapeurs organiques qui, se combinant à la vapeur d’eau évacuée, forme la créosote. Ces vapeurs se condensent dans le conduit relativement froid de la cheminée d’un appareil brûlant lentement et, lorsqu’elle prend feu, la créosote produit un feu extrêmement chaud.
  • Page 64 NETTOYAGE DE LA CHEMINÉE La cheminée et l’appareil doivent être inspectés et nettoyés s’il y a lieu au moins une fois l’an. En cas d’utilisation fréquente du chauffage au bois, le nettoyage de la cheminée doit être fait au besoin pour éviter des feux de cheminée.
  • Page 65 COLLECTEUR D’AIR SECONDAIRE À la fi n de chaque saison de chauffage, inspectez le tuyau d’air secondaire pour déceler des signes de déformation ou de détérioration. Remplacez-le si nécessaire. À ce moment, vérifi ez également que le joint d’étanchéité de la porte n’est pas usé ou desserré. Remplacez-le par une corde de ½ po (12,7mm) en fi bre de verre à...
  • Page 66 SOINS DE LA VITRE Si vous ne nettoyez pas les dépôts régulièrement, la vitre risque de rester ATTENTION marquée en permanence. Normalement, un feu très chaud maintiendra la vitre propre. Les raisons les plus fréquentes pour lesquelles la vitre se salit sont : trop UNE SURFACE VITREE CHAUDE peu de combustible est utilisé...
  • Page 67 BOIS AVERTISSEMENT CET APPAREIL A ÉTÉ CONÇU POUR BRÛLER DU BOIS NATUREL UNIQUEMENT. NE BRÛLEZ PAS DE BOIS TRAITÉS, DE CHARBON DE BOIS, DE CHARBON, DE PAPIERS DE COULEUR, DE CARTONS, DE SOLVANTS NI DE DÉCHETS. CET APPAREIL N’A PAS ÉTÉ TESTÉ AVEC UN ENSEMBLE DE BÛCHES À GAZ NON VENTILÉES. AFIN DE RÉDUIRE LE RISQUE D’INCENDIE OU DE BLESSURE, N’INSTALLEZ PAS D’ENSEMBLE DE BÛCHES À...
  • Page 68 9.0 RECHANGES Contactez votre détaillant ou le fabricant pour les questions concernant les prix et la disponibilité des pièces de rechange. Normalement, toutes les pièces peuvent être commandées chez votre détaillant autorisé. POUR UN REMPLACEMENT DE PIÈCE SOUS GARANTIE, UNE PHOTOCOPIE DE LA FACTURE ORIGI- NALE SERA REQUISE AFIN DE POUVOIR HONORER LA DEMANDE.
  • Page 69 W415-1482 / 10.09.15...
  • Page 70 10.0 GUIDE DE DÉPANNAGE AVERTISSEMENT COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. L’APPAREIL PEUT ÊTRE CHAUD. ATTENDEZ QU’IL SOIT REFROIDI AVANT D’EN FAIRE L’ENTRETIEN. N’UTILISEZ PAS DE PRODUITS D’ENTRETIEN ABRASIFS. LORSQUE VOUS VÉRIFIEZ DES CONNEXIONS, QUE VOUS INSTALLEZ DES FILS DE DÉRIVATION (POUR EFFECTUER DES TESTS UNIQUEMENT) OU QUE VOUS REMPLACEZ DES COMPOSANTS, DÉBRANCHEZ L’APPAREIL DU RÉCEPTACLE AFIN D’ÉVITER LES CHOCS ÉLECTRIQUES OU DES DOMMAGES AUX COMPOSANTS.
  • Page 71 11.0 GARANTIE Les produits CONTINENTAL® sont fabriqués conformément aux normes strictes du Certifi cat d’Assurance de Qualité ISO 9001 : 2008 mondialement reconnu. Les produits CONTINENTAL® sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi és qui sont fi ers de leur travail. Une fois assemblé, chaque appareil est soigneusement inspecté par un technicien qualifi...
  • Page 72 W415-1482 / 10.09.15...