5.3
BRICKS AND BAFFLE INSTALLATION
EN
OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE
With appliance and chimney installation completed, move the bricks into place for your appliance as
illustrated.
A.
Install the bottom bricks, working from the back of the appliance forward.
B.
Before installing the back bricks, loosen the screw holding the brick retainer and insure that it has
been moved forward. Install the six bricks along the back wall by pivoting the bricks up under the brick
retainer. Re-tighten the screw.
C.
Install the fi rst two rows of side bricks as shown. Pivot the fi bre baffl e into place with the brick retainter
down and toward the outside of the unit. Slide the top row of bricks into place to support the baffl e. The
baffl e must sit fl at on the outside row of bricks as well as the fl ange on the manifold shield. Push the
baffl e all the way to the rear of the fi rebox, leaving a minimum of 1" (25.4 mm) gap along the front. This
will allow fl ue gases to escape the fi rebox.
D.
Install the 4 bricks along the front opening.
NOTE: Do not operate if baffl e and manifold shield are not in position.