Controlling The Extraction Tower; Extractor Hood Control Panel; User Modes; Exhaust Mode - Novy One Power Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6 CONTROLLING THE EXTRACTION
TOWER

6.1 Extractor hood control panel

Extraction control
Switch on/lift extraction tower position
Decrease extraction speed
Increase extraction speed
Switch off/lower extraction tower position
Extraction speed indication
1
Cleaning indication for grease filter
Cleaning indication for recirculation filter (optional)

6.2 User modes

This device can be used in the exhaust or recirculation mode
(standard setting upon delivery)

6.2.1 Exhaust mode

The air sucked in is first cleaned by the grease filters before
being removed to the outside. This can be achieved by making
use of a series of channels connected between the device and
a wall exhaust cover.
To set the device in exhaust mode, press and hold the key
+
combination
and
and
extraction tower is closed.
The led next to the Cleaning indication for recirculation filter will
blink 3x.

6.2.2 Recirculation mode

The air sucked in is first cleaned by the grease filters. The
scents are then removed in the Monoblock recirculation filter
before re-entering the kitchen.
6
6
6
7
1
5
1
2
5
1
2
3
6
2
3
4
5
6
1
2
6
5
1
1
2
3
for 3 seconds when the
To set the device in recirculation mode (default setting), press
and hold the key combination
when the extraction tower is closed.
The led next to the Cleaning indication for recirculation filter will
be on for 3 seconds.
6
7
7
7
5
5

6.3 Switch on and off and run-out function

2
3
3
4
4
7
WARNING: When the extraction is activated, the
extraction tower automatically rises to the desired
7
height at the rear of the induction hob. Therefore,
3
4
ensure nothing can hinder its movement.
7
5
2
3
4
4
Switch on
Press
and hold for 2 seconds
Switch on run-out function
Press
Switch off run-out function
Press
Run-out function: This function starts at the end of cooking.
For a fixed time, the remaining cooking vapours will be extracted
from the kitchen by the extraction tower at low extraction mode
and at a height of 10 cm. When recirculation is selected, the
Monoblock filters are also dried.
The run-out time is set to 30 minutes by default in the recirculation
mode and 10 minutes in exhaust mode. It is recommended that
this function be allowed to carry out its function completely. At
the end of the run-out time, the motor and the extraction tower
will automatically switch off and the tower will close.
– 66 –
+
and
and
4
Extraction tower
for 3 seconds
Display
LED
lights up
1st LED
lights up
LED
off

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

One pro180118111801 one power1811 one pro