Télécharger Imprimer la page

WAGNER W 400 Manuel D'instructions page 34

Publicité

Les langues disponibles

Les langues disponibles

GB
Problem
Poor covering
capacity on the wall
21. Technical Data
Max. viscosity
Power source
Power consumption
Atomizing output
Max. flow rate
Protection Class:
Sound pressure level*
Sound pressure output*
Oscillation level*
Weight
* Measured in accordance with EN 60745-1
Information about the oscillation level
The specified oscillation level has been measured according to a standard test
procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational
strain.
Attention! The vibration emission value can differ from the specified value when the
electric tool is actually in use, depending on how the electric tool is being used. It is
necessary to specify safety measures to protect the operating personnel. These measures
are based on an estimated shutdown during the actual conditions of use (all parts of the
operating cycle are taken into consideration here, for example periods when the electric
tool is switched off, and, when it is switched on but running without any load).
28
Cause
Spray material is too cold
Highly absorbent surface or paint
with poor covering capacity
Distance too large
Technical Data
3400 mPas
230 V, ~ 50 Hz
460 W
110 W
230 ml/min
I
81 dB (A); Uncertainty K = 3 dB
92 dB (A); Uncertainty K = 3 dB
< 2.5 m/s²; Uncertainty K = 1.5 m/s²
1.7 kg
Remedy
➞ The material you are
spraying should be at
room temperature
➞ Cross spray (Fig. 8)
➞ Closer to the object
/ 240 V, ~ 50 Hz
/ 485 W
W 400

Publicité

loading