67070-06-11.qxd:skabelon-A4
6.7.3. Adaptive function
Here you can activate/deactivate (On/Off) the
adaptive function. This function is only related
to the 4-event timer and only works in
connection with going from one event to
another where the temperature is going to be
raised. The adaptive function finds out when the
thermostat shall start heating to ensure that the
right temperature is reached at the time that it
has been programmed for.
6.7.4. Offset
Offset is used to compensate for any difference
between the thermostat and a room
thermometer. If the thermometer, for instance,
shows 1°C more than the thermostat, it is
possible to adjust the offset by +/- 5°C. Then
the thermostat will show the same temperature
as the thermometer. If the thermostat for
example shows 1 degree too much, offset
should be set to +1. Then the temperature will
be set 1 degree lower.
Offset applies to both built-in and external
sensors whereas the limit sensor, if any, is not
affected.
6.7.6. Reset
• Reset 2: Reset values defined in Engineer
settings to factory settings.
• Reset 3: Equal to Reset 2, except history
data are deleted. The number of relay
connections is not deleted, though.
7. Error Messages
If you get an error the LED is flashing red.
Internal failure The thermostat is defective,
replace thermostat
External failure External sensor or heating
unit is defective.
4
29/06/11
9:16
Side 4
8. Factory settings
The thermostat is delivered with factory set programs as follows:
Day 1-5
Event
Day
Out
Home
Night
Day 6-7
Event
Day
Night
9. Appendix
9.1. Table of Compatibility
Undertile
Underlaminate
Undercarpet
Inscreed
Type A
Type B
User Defined
9.2. Heat Definitions
Undertile
Underlaminate
Undercarpet
Inscreed
Type A
Type B
User Defined
Configuration
A
B
C
D
E
n/a = not available
© 2011 OJ Electronics A/S
Time
With floor sensor
06:00-08:00
08:00-16:00
16:00-22:30
22:30-06:00
Time
With floor sensor
08:00-23:00
23:00-08:00
Tiles
Stone
Laminate
Wood
YES
YES
NO
NO
NO
NO
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
Tiles
Stone
Laminate
Wood
A
A
n/a
n/a
n/a
n/a
B
B
n/a
n/a
B
B
A
A
B
B
D
D
n/a
n/a
n/a
n/a
n/a
n/a
E
E
E
E
Control temperature
Room
Min. Max.
Min. Max.
5
30
5
5
27
5
5
25
5
5
30
5
prog
With air sensor
25°C
20°C
20°C
15°C
25°C
22°C
20°C
15°C
With air sensor
25°C
22°C
20°C
15°C
Carpet
Vinyl
Other
NO
NO
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
Carpet
Vinyl
Other
n/a
n/a
E
n/a
n/a
E
C
C
E
C
C
E
n/a
n/a
E
C
C
E
E
E
E
Overheat
Floor
Max.
40
40
27
27
25
27
50
55
prog
prog