Télécharger Imprimer la page

LG WKGX201HBA Manuel D'utilisation page 51

Publicité

Les langues disponibles

Les langues disponibles

en-us_main.book.book Page 51 Friday, December 2, 2022 4:27 PM
Operation
Problem
TM
The Flow Sense
After clearing the restrictions, the Flow Sense
consecutive cycles to determine that the performance value has improved before the
(
) indicator
W
remains active after
Flow Sense
clearing the
• If the Flow Sense
restriction in the
venting.
Clothes take too long
Exhaust ducts are blocked, dirty, or duct run is too long.
to dry.
• Confirm that the exhaust duct is properly configured and free of debris, lint, and
Load is not properly sorted
• Separate heavy items from lightweight items. Larger and heavier items take longer to dry.
Large and heavy fabrics are loaded.
• Heavy fabrics take longer to dry because they tend to retain more moisture. To help
Dryer controls are not set properly.
• Use the appropriate control settings for the type of load you are drying. Some loads may
Lint filter needs to be cleaned.
• Remove the lint from the filter before every load. With the lint removed, hold the filter up
House fuse is blown, circuit breaker has tripped, or power outage has occurred.
• Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a
The appliance is overloaded.
• Divide extra large loads into smaller loads for better drying performance and efficiency.
Energy Saver option is selected. (on some models)
• If using the Normal cycle, deselect the Energy Saver option that is selected by default.
The appliance will
Power cord is not properly plugged in.
not turn on.
• Make sure that the plug is securely plugged into a grounded outlet matching the
House fuse is blown, circuit breaker has tripped, or power outage has occurred.
• Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a
The appliance does
House fuse is blown, circuit breaker has tripped, or power outage has occurred.
not heat.
• Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a
Gas supply or service is turned off.
• Confirm that the house gas shutoff and the shutoff valves of the dryer are both fully open.
TM
(
) indicator is reset.
W
TM
(
) indicator remains active for more than five cycles after the
W
restriction has been cleared, call for service.
obstructions. Make sure that the outside wall damper can open properly and is not
blocked, jammed, or clogged.
Light items in a load with heavy items can fool the sensor because the light items dry
faster.
reduce and maintain more consistent drying times for large and heavy fabrics, separate
these items into smaller loads of a consistent size.
require an adjustment of the dry level setting for proper drying.
to a light to see if it is dirty or clogged. With some loads that produce high amounts of lint,
such as new bath towels, it may be necessary to pause the cycle and clean the filter during
the cycle.
circuit overload, have it corrected by a qualified electrician.
This option reduces enery use by adding an air dry section to the beginning of the cycle. It
is normal to feel no heat at the beginning of the cycle while in Energy Saver mode.
appliance's rating plate.
circuit overload, have it corrected by a qualified electrician.
circuit overload, have it corrected by a qualified electrician.
Even if gas is not supplied to the appliance, it will run and no error codes will display. Verify
that other gas appliances in the home are working normally.
TROUBLESHOOTING
Possible Cause & Solution
TM
(
) system requires multiple,
W
51

Publicité

loading

Ce manuel est également adapté pour:

Wkgx201h a serieWkex200h a serie