6
Cause of Faults, Remedial Action
► Outlet pressure rises above set value
Seal is dirty or cone seal leaking.
Remedial action:
Clean taper or replace if necessary.
► Outlet pressure falls below zero consumption
Seal untight, or spring hood insufficiently tightened.
Remedial action:
Replace seal, or retighten spring hood.