Switch off the voltage on all-poles of the pump and secure against unauthorised restart!
Always deactivate the power supply from the pump and if necessary SSM and SBM!
Due to the presence of dangerous contact voltage, work on the module must not be started until
5 minutes have elapsed!
Check whether all connections (even potential-free contacts) are voltage-free!
The pump may still be live even in voltage-free state. The rotor induces a contact voltage, which is also
present at the motor contacts. Close the existing shut-off devices in front of and behind the pump!
If the control module/cable is damaged, do not operate the pump!
In case of impermissible removal of operating and settings elements on the control module, there is a risk
of electrical shock if inner electrical components are touched!
9.3
Dismantling/installation
Before any dismantling/installation operation, make sure that the "Shutdown" section has been taken
into consideration!
WARNING
Risk of burns!
Incorrect dismantling/installation can result in personal injury and material damage.
Depending on the operating status of the pump and the system (fluid temperature), the en-
tire pump can get very hot.
There is a severe risk of burns from simply touching the pump!
Allow the system and pump to cool to room temperature!
WARNING
Risk of scalding!
The fluid is under high pressure and can be very hot.
There is a risk of scalding due to escaping hot fluid!
Close shut-off devices on both sides of the pump!
Allow the system and pump to cool to room temperature!
Drain the shut-off branch of the system!
If no shut-off devices are fitted, drain the system!
Follow the manufacturer's instructions and safety data sheets for possible additives in the system!
WARNING
Danger of injury!
Danger of injury caused by falling motor/pump after loosening the fastening screws.
Comply with national regulations for accident prevention and also with the operator's internal work, com-
pany and safety regulations. If necessary, wear protective clothing and equipment!
Installation and operating instructions • Wilo-Stratos PARA-C/-CZ • Ed.01/2023-04