EN
CRATEWASH DOSING SYSTEM
1.3
TECHNICAL SPECIFICATIONS
Power supply: 100-240 Vac or 50/60 HZ:
Power range for selectable signals: 24...240 Vac or 160...240 Vac:
Power consumption: 40 W
Fuse: 1.6A
Pump 1 flow rate: 20/40/60/80 l/h
Pump 2 flow rate: 7 l/h
Conductivity range with inductive probe: 1 mS ... 10 mS or 1 mS ... 100 mS
System protection: IP 55 Weight: 3.5 Kg
WARNINGS
 Ensure that the pressure in the injection point of the additive is not higher than 3 bars.
 Ensure that the suction pipes are inserted in the correct product tanks.
 Check, with the use of a multimeter, all electrical connections to the system. The application of
incorrect power may cause permanent damage to equipment not covered by the guarantee. Avoid
connecting to power supplies subject to wide changes in power and/or power variations. For more
information on any electrical connection, refer to the wiring diagram in this manual.
Check the power of the main supply and make sure it is within the range of 80 to 265 Vac.
 CAUTION: Within the system circuits there are high power points that may be dangerous for the
operator.
Always remove the power supply before performing any maintenance tasks in the
equipment.
 CAUTION: During the installation and execution of the electrical connections, switch off the power
supply from the washing machine.
 Failure to comply with the guidelines contained in this manual may result in damages to things of
people, compromise the operation of the equipment or damage it.