CRATEWASH DOSING SYSTEM
10.3.5
ALARM SUBMENU
ALARMS
Buzzer
Active
<-
Level Input
N. A.
<-
1st Pump Level
Not Active
<-
2nd Pump
level
Alarm Active <-
OFA
999 sec
<-
OFA 2
Block
<-
SOS OFA2 Restore
20sec
<-
<
For more information on the alarms managed by the system, displays and restore conditions, see
Paragraph 11 of this manual.
0000137384
Activates or disables the buzzer in the presence of an alarm condition
Configures the type of level probes connected to the system: Normally Open or
Normally Closed. The former close the contact inside when there is no chemical
product; the latter do exactly the opposite.
Activates or disables the Primary Pump level alarm. Obviously, in order to use
this alarm, it is necessary to connect a level probe to the corresponding
connector. The alarm blocks the individual pump and activates the alarm buzzer
and relay. The alarm can be stopped by replenishing the chemical product.
Same as the previous option, but relate to the Secondary Pump.
Programs the time allotted for the system to reach the SetPoint. If the
conductivity does not reach this value within that timeframe, the system is in an
alarm condition and the relay and buzzer are activated, although the pumps
continue dispensing.
It schedules tasks after a time equal or double to the time of the OFA. It can
choose if the system is Blocked, if it has to stop dispensing, or if it needs to begin
working in an Emergency mode, regulated by the following parameters.
This option is only present if OFA 2 is programmed as Emergency, and it
programs the time for which the Primary Pump pump will be activated in
presence of the Secondary Trigger
Rev. 2.4