b)
Analogue input functions
I. JOB mode - Without settings
All parameter settings stored in JOB mode are used (the values of inputs 1, 2 and 3 are, therefore, not taken into account).
DIP2-SWITCH 1 = OFF (Mode: JOB)
DIP2-SWITCH 4 = OFF (JOB LOCK)
ON
1 2
3 4
Table of adjustable values:
SAM-1A input
Pin Connector
INPUT_1
INPUT_2
INPUT_3
INPUT_4
II. JOB mode - SAM-1A settings
The welding current value (JOB mode's Weld_Current parameter) is disregarded (the value is taken from the SAM-1A's input).
DIP2-SWITCH 1 = OFF (Mode: JOB)
DIP2-SWITCH 4 = ON (JOB UNLOCK)
ON
1 2
3 4
Table of adjustable values:
SAM-1A input
Pin Connector
INPUT_1
INPUT_2
INPUT_3
INPUT_4
Setting
X20-1
X20-2
Current type (Titanium only)
X20-4
JOB number
X20-3
ARC_LEN
X20-1
WELD_CURRENT
X20-2
Current type
X20-4
(Titanium only)
JOB number
X20-3
SAM-1A
-
-
Setting
Value
-
-
<5 V = DC
>5 V = AC
between 0 - 20
Value
0 V = -6
5 V = 0
10 V = +6
0 V = minimum power source value
10 V = maximum power source value
<5 V = DC
>5 V = AC
between 0 - 20
EN
33