Function
Average cycle Current
Start Process
Welding Process
GAS ON
Arc detect
Main Current
C)
SCHEMATIC DIAGRAM IN CASE OF AN ERROR
Function
Average cycle Current
Error state
Authorised Start
Gas ON
7.
MAINTENANCE
UPDATES
Before using the product for the first time, it is recommended to check whether a new software update is available on the GYS
after-sales service site (customer code required).
A single update allows the user to update all connected products (power source, remote control, wire-feed reel and SAM,
etc).
1- Disconnect all devices from the network.
2- Connect a USB key containing the latest updates to the
specific USB port and start the device.
3- The screen comes on if a new software version is detec-
ted. Wait until the step is complete and restart the product
after having disconnected the USB key.
26
SAM-1A
Welding cycle
Pregas
Start
Upslope
Error
Welding
Downslope
Welding
Downslope
Stop
EN
Emitter
Stop
Post-gas
CPU
SAM
SAM
SAM
SAM
Emitter
Post-gas
SAM
SAM
SAM
SAM