Télécharger Imprimer la page

Toparc SAM-1A Manuel D'utilisation page 28

Publicité

Les langues disponibles

Les langues disponibles

APPENDIX 1 - SAM-1A SETTINGS USING THE NEOPULSE/PULSEMIG
1.
NEOPULSE/PULSEMIG digital inputs/outputs
a)
Digital inputs ..................................................................................................................................................................... 28
b)
Digital outputs ................................................................................................................................................................... 28
2.
NEOPULSE/PULSEMIG analogue inputs/outputs
a)
Analogue outputs ............................................................................................................................................................... 28
b)
Analogue input functions .................................................................................................................................................... 29
I.
JOB mode - Without settings ........................................................................................................................................ 29
II.
JOB mode - Current settings ........................................................................................................................................ 29
III.
JOB mode - Wire-speed settings ................................................................................................................................... 30
IV.
Manual Mode .............................................................................................................................................................. 30
Where to find the JOB number
3.
Where to find the synergy values
4.
How to change the management mode to find the min./max. setting values
5.
1.
Digital inputs/outputs for NEOPULSE/PULSEMIG machines
a)
Digital inputs
The SAM-1A has four digital inputs as detailed below:
MMI_LOCK
Start_Process
Start_Gaz
Wire_Feed
(only in MIG)
b)
Digital outputs
As well as the following four digital outputs:
Error
Authorised_Start
Arc_Detect
Welding_Process
Main_Current
2.
NEOPULSE/PULSEMIG analogue inputs/outputs
a)
Analogue outputs
The SAM-1A has two analogue outputs providing voltage- and current-measurement information as follows:
Voltage measurement (M_Weld_Voltage, X20-5): varies from 0 - 10 V and covers a measurement range of 0 - 50 V.
Current measurement (M_Weld_Current, X20-15): varies from 0 - 10 V and covers a measurement range of 0 - 500 A.
28
....................................................................................................................................
..............................................................................................................................
Pin
Connector
Current-Voltage multimeter mode
X20-18
Stopping the welding process
X20-19
GAS solenoid valve closed
X20-20
X20-16
Pin
Connector
X20-6
Welding prohibited
X20-7
Arc not detected
X20-14
No welding in progress
X20-8
Outside the main welding phase
X20-13
SAM-1A
.....................................................................................................
...............................................................................................
0
Wire stopped
0
No error
......................................
Status
1
Accessing the power source settings
Starting the welding cycle
GAS solenoid valve open
Unwinding the wire
Status
1
Error detected
Welding permitted
Arc detected
Welding in progress
In the main welding phase