Télécharger Imprimer la page

Toparc SAM-1A Manuel D'utilisation page 32

Publicité

Les langues disponibles

Les langues disponibles

APPENDIX 2 - SAM-1A SETTINGS USING THE TITAN/TITANIUM
1.
Digital inputs/outputs
a)
Digital inputs ..................................................................................................................................................................... 32
b)
Digital outputs ................................................................................................................................................................... 32
2.
Analogue input/outputs
a)
Analogue outputs ............................................................................................................................................................... 32
b)
Analogue input functions .................................................................................................................................................... 33
I.
JOB mode - Without settings ........................................................................................................................................ 33
II.
JOB mode - SAM-1A settings ....................................................................................................................................... 33
III.
Tracking Mode............................................................................................................................................................. 34
Where to find the JOB number
3.
1.
The TITAN/TITANIUM'S DIGITAL INPUTS/OUTPUTS
a)
Digital inputs
The SAM-1A has four digital inputs as detailed below:
MMI_LOCK
Start_Process
Start_Gaz
Wire_Feed
(only in MIG)
b)
Digital outputs
As well as the following four digital outputs:
Error
Authorised_Start
Arc_Detect
Welding_Process
Main_Current
2.
The TITAN/TITANIUM'S ANALOGUE INPUTS/OUTPUTS
a)
Analogue outputs
The SAM-1A has two analogue outputs providing voltage- and current-measurement information
as follows:
Voltage measurement (M_Weld_Voltage, X20-5): varies from 0 - 10 V and covers a measurement range of 0 - 50 V.
Current measurement (M_Weld_Current, X20-15): varies from 0 - 10 V and covers a measurement range of 0 - 500 A.
32
....................................................................................................................................................
.................................................................................................................................................
....................................................................................................................................
Pin Connector
Current-Voltage multimeter mode
X20-18
Stopping the welding process
X20-19
GAS solenoid valve closed
X20-20
X20-16
Pin Connector
X20-6
X20-7
X20-14
No welding in progress
X20-8
Outside the main welding phase
X20-13
SAM-1A
0
Wire stopped
0
No error
Welding prohibited
Arc not detected
Status
1
Accessing the power source settings
Starting the welding cycle
GAS solenoid valve open
Unwinding the wire
Status
1
Error detected
Welding permitted
Arc detected
Welding in progress
In the main welding phase
EN
32
32