b)
Analogue input functions
I. JOB mode - Without settings
All parameter settings stored in JOB mode are used (the values of inputs 1, 2 and 3 are, therefore, not taken into account).
DIP2-SWITCH 1 = OFF (Mode: JOB)
DIP2-SWITCH 2 = OFF
DIP2-SWITCH 4= OFF (JOB LOCK)
ON
1 2
3 4
Table of adjustable values:
SAM-1A input
Pin Connector
INPUT_1
INPUT_2
INPUT_3
INPUT_4
II. JOB mode - Current settings
The current parameter setting values, Arc_LEN, Self and Weld_Current in JOB mode are disregarded (the values are taken from the
SAM-1A inputs).
DIP2-SWITCH 1 = OFF (Mode: JOB)
DIP2-SWITCH 2 = OFF (Management: Current)
DIP2-SWITCH 4 = ON (JOB UNLOCK)
ON
1 2
3 4
Table of adjustable values:
SAM-1A input
Pin Connector
INPUT_1
INPUT_2
INPUT_3
INPUT_4
Setting
X20-1
-
X20-2
-
X20-4
-
JOB number
X20-3
Setting
ARC_LEN
X20-1
WELD_CURRENT
X20-2
SELF
X20-4
JOB number
X20-3
SAM-1A
Value
between 1 - 20
-
-
-
Value
0 V = -6
5 V = 0
10 V = +6
0 V = minimum synergy value
10 V = maximum synergy value
0 V = -4
5 V = 0
10 V = +4
between 0 - 20
EN
29