III. JOB mode - Wire-speed settings
The parameter setting values, Arc_LEN, Self and Wire_Weld_Speed in JOB mode are disregarded (the values are taken from the
SAM-1A inputs).
DIP2-SWITCH 1 = OFF (Mode: JOB)
DIP2-SWITCH 2 = ON (Management: Wire speed)
DIP2-SWITCH 4 = ON (JOB UNLOCK)
ON
1 2
3 4
Table of adjustable values:
SAM-1A input
INPUT_1
INPUT_2
INPUT_3
INPUT_4
IV. MANUAL Mode
DIP2-SWITCH 1 = ON (Mode: MANUAL)
ON
1 2
3 4
Table of adjustable values:
SAM-1A input
INPUT_1
INPUT_2
INPUT_3
INPUT_4
30
Pin Connector
X20-1
WIRE_WELD_SPEED
X20-2
X20-4
JOB number
X20-3
Pin Connector
WELD_VOLTAGE
X20-1
WIRE_WELD_SPEED
X20-2
X20-4
X20-3
SAM-1A
Setting
ARC_LEN
SELF
Setting
CHOKE
-
Value
0 V = -6
5 V = 0
10 V = +6
0 V = minimum synergy value
10 V = maximum synergy value
0 V = -4
5 V = 0
10 V = +4
between 0 - 20
Value
0 V = 0 V
10 V = 50 V
0 V = minimum synergy value
10 V = maximum synergy value
0 V = -4
5 V = 0
10 V = +4
-
EN