Connect the Wiring
Risk of electric shock. Electrical wiring must be done by qualifi ed
personnel in accordance with all applicable codes and standards.
Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power from being switched
on accidentally.
1 ] Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under GREEN ground screw.
2 ] Reinstall wiring cover and attach it to the hood using its retaining screw.
Ensure both tabs on inner top of hood are engaged in their corresponding slots in
wiring cover. Also, make sure not to pinch wires while reinstalling wiring cover.
Install the Filters
Ducted Installation Only:
Re-install grease filters removed in step 2 , page 9, under "Prepare the Hood" .
Non-ducted Installation Only:
Purchase two non-ducted filters from your local distributor or retailer (see product specification
label for filter type). Attach the non-ducted filters following instructions packed with the
non-ducted filter.
!
WARNING
HOUSE
POWER CABLE
!
CAUTION
MOTOR
GROUND
WIRE
GROUND
SCREW
TABS ON INNER
TOP OF HOOD
ENGAGED IN
SCREW
WIRING COVER
SLOTS.
19