Error Messages
Symptom
The LED displays
and all the lights
flash
The LED displays
and all the lights
flash
The LED displays
and all the lights
flash
The LED displays
and all the lights
flash
The LED displays
and all the lights
flash
The LED displays
and all the lights
flash
The LED displays
CAUTION: YOU MUST ENSURE THE PUMP IS UNPLUGGED
BEFORE BEGINNING SPA MAINTENANCE OR SEVERE RISK OF
INJURY OR DEATH EXISTS.
Filter Cartridge Cleaning / Replacement
NOTE: To ensure water stays clean, please clean the filter cartridge
every day and change the filter cartridges every two weeks.
1. Unplug the pump.
2. To prevent water from escaping when cleaning or
replacing the filter cartridge, reach inside the spa and
insert the three stopper caps onto the spa's inside
adapter and skimmers.
3. Remove the top of the pump by unscrewing the cap
retainer.
4. Remove the cap.
5. Remove the filter cartridge by lifting it straight out of
the pump housing.
6. The filter cartridge can be rinsed off with a garden
hose and reused. However, if the filter cartridge remains
soiled and discolored the filter cartridge should be
replaced. It is recommended to replace filter cartridges
every two weeks.
7. Insert the cleaned filter cartridge into the center of the
pump's housing.
8. Check to make sure the pump cap seal is placed
correctly on the top rim of the housing.
9. Replace the pump cap back into position.
10. Replace the pump cap retainer and lock it into
position by turning it clockwise.
11. Reach inside the spa and remove the three stopper
caps from the spa's adapter and skimmers. This will
allow water to flow into the pump.
12. Using the previously outlined steps, test the RCD/PRCD
plug, bleed the air purge valve, and restart the pump.
All manuals and user guides at all-guides.com
Problem Causes
The household power supply is not
equipped with a residual current device.
System error.
No water flow.
Water temperature too low.
Water temperature too high.
Something is wrong with the pump.
After 24 hours of operation, the pump
will hibernate and the rapid heating and
water filtration functions are disabled.
MAINTENANCE
P4014Q09-01-01
P4014Q09-01-03
P4014Q09-01-04
9
Solutions
Turn to a qualified electrican.
Replug the RCD plug. (If this does not solve the
problem, please consult Bestway or your dealer).
If the adapters of the pump & the spa are blocked
or the filter cartridge is too dirty . Replace the filter
cartridge if necessary. (If this does not solve the
problem, please consult Bestway or your dealer).
If the environment temperature is below 4ºC we
recommend not to use the spa or pump.
Unplug the pump. When the water cools
restart (If this does not solve the problem please
consult Bestway or your dealer).
Consult Bestway or your dealer.
To re-active the pump simply press any button on
the control panel.
P4014Q09-01-01 / Air Purge Valve
/ Air Purge Valve Seal
P4014Q09-01-03 / Pump Cap Retainer
P4014Q09-01-04 / Pump Cap
/ Pump Cap Seal
/ Filter Cartridge
Adapter C Seal
Adapter A Seal
Adapter B Seal
S-S-000830