Télécharger Imprimer la page

Vimar Elvox EKKO ART 200D Manuel Pour Le Raccordement Et L'emploi page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
CONTROL ACCESSORIES OPERATION
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE
CONNECTED.
Make sure that any other type of command accessories (e.g.
mass detectors) used on the installation are set in the IMPULSIVE
mode, otherwise, the gate will be operated even without the
protection of the safety devices.
STEP-BY-STEP BUTTON (COM-K BUTTON)
If DIP6 OFF => It cyclically performs the commands open-stop-close-stop-
open etc.
If DIP6 ON => Opens the gate when closed. There is no effect if activated
while opening. If activated when gate is open, the gate
closes. If activated while closing, the gate reopens.
OPEN BUTTON (COM-OPEN)
The button controls the opening movement when the gate is stationary. If
activated while closing, it reopens the gate.
CLOCK FUNCTION OF OPEN BUTTON
ATTENTION: A CLOCK CONNECTED TO RS12 ACTIVATES THE
OPENING MOVEMENT OF THE GATE WITHOUT HAVING THE
PROTECTION OF THE SAFETY DEVICES!
CLOSE BUTTON (COM-CLOSE)
Controls the closing movement when the gate is stationary.
REMOTE CONTROL
If DIP6 OFF => It cyclically performs the commands open-stop-close-stop-
open etc.
If DIP6 ON => Opens the gate when closed. There is no effect if activated
while opening. If activated when gate is open, the gate
closes. If activated while closing, the gate reopens.
PEDESTRIAN OPEN BUTTON (COM-PED.BUTT.)
Partial opening and closing control.
During pedestrian opening, pausing or closing, you can control the opening
of any command linked to the RS12 board.
With DIP 6 you can choose the operation mode of the pedestrian push
button.
If DIP6 OFF => It cyclically performs the commands open-stop-close-stop-
open etc.
If DIP6 ON => Opens the gate when closed. There is no effect if activated
while opening. If activated when gate is open, the gate
closes. If activated while closing, the gate reopens.
ELECTRIC LOCK (LOCK)
Set DIP 8 to ON to enable control of the electric lock when opening.
ELECTRIC LOCK PULSE RELEASE IN OPENING
Set DIP 9 to ON to enable the electric lock pulse release when opening
(provided DIP 8 is ON).
If a command to open the gate is given when the gate is closed, the
closing movement is performed for 0.5 seconds and the electric lock is
simultaneously activated (followed by a 0.5 second pause and then the
opening of the gate).
ELECTRIC LOCK PULSE ENGAGEMENT
Set DIP 10 to ON to enable the pulse engagement of the electric lock when
closing. Upon closing, motors are activated for 0.5 seconds at full voltage
to ensure lock engagement.
EASY MOTOR RELEASE
Set DIP 11 to ON to enable easy manual release (provided that DIP 10 is
ON), upon closing a reverse motion with a fixed time of 0.2 seconds occurs
to facilitate manual release.
EN
All manuals and user guides at all-guides.com
OPERATION OF SAFETY ACCESSORIES
PHOTOCELL (COM-PHOT)
DIP 4 OFF => if an obstacle is placed in range of the photocells when the
gate is closed, the gate does not open. During operation,
photocells work when opening (by starting the opening
movement only after the obstacle is removed) and closing
(by starting the reverse movement only after the obstacle is
removed).
DIP 4 ON => if an obstacle is placed in range of the photocells when
the gate is closed and the command to open is given, the
gate opens (the photocells do not work while opening).
Photocells work only during closing (with reverse motion
restored after a second, even if they are still engaged).
CONTROL OF IMMEDIATE CLOSING AFTER MOVEMENT IN FRONT
OF PHOTOCELLS
DIP 16 ON and DIP 4 OFF => if photocells are engaged during opening,
the gate stops and the gate only closes
one second after the photocells are
disengaged.
DIP 16 ON and DIP 4 ON => if photocells are engaged during opening,
the gate continues to open. Upon
disengagement of the photocells, the gate
stops and reverses closing motion after a
one second pause.
If total opening is reached (end of
opening
is deactivated and automatic time
closing is activated (if TCA trimmer is
activated and LED DL6 is on). If during
closing there is a rapid movement (e.g.
pedestrian) the gate will open again for
two seconds and then close once again.
DIP 12 OFF =>
immediate closing after movement in front
of the photocells is deactivated.
N.B.: Please check photocell operation at least every six months.
EDGE (SAFETY STRIP) (COM-EDGE)
If engaged during opening, reverses the motion when closing.
If engaged when closing, reverses the motion when opening.
If it remains engaged again, it performs a further reversal after 2 seconds,
then performs an additional short reversal and then gives the sensor failure
or engaged alarm (N.O. contact).
If the sensor remains engaged (N.O. contact) no movement is allowed.
If not used, jump the terminals COM-EDGE.
MONITORING OF SAFETY SENSORS (A+ TEST A-)
Sensors can be monitored through the A+ TEST input and DIP 12 ON.
The monitoring consists of a functional test of the sensor run after every
full gate opening.
Closing the gate is therefore permitted only if the sensors have passed the
functional test after each opening.
CAUTION: MONITORING OF THE SENSOR INPUT CAN BE ACTIVATED
WITH DIP 12 ON OR DEACTIVATED WITH DIP 12 OFF. IN FACT, THE
FUNCTIONAL TESTING OF SENSORS IS 'POSSIBLE ONLY IF THESE
DEVICES HAVE THEIR OWN POWER SUPPLY.
A MECHANICAL SENSOR CAN NOT BE MONITORED, SO DIP 12
SHOULD BE SET TO OFF.
SENSOR AUTOTEST ALARM (DIP 12 ON)
If the sensor fails the monitoring test after opening, an alarm is displayed by
the blinker lighting up. Gate closure is not allowed in this condition. Normal
operation can be restored only by repairing the sensor and pressing one of
the activated controls.
STOP BUTTON (COM-STOP)
The STOP button stops the gate during any operation.
If held when the gate is fully open (or partially when using the pedestrian
control) automatic closing is temporarily deactivated (if activated by the
TCA trimmer and LED DL6 on). It is therefore necessary to use a new
command to make it close.
The automatic closing function is reactivated on the next cycle (if activated
by the TCA trimmer and LED DL6 on).
POWER SENSOR ALARM
The RS12 control panel has automatic sensors that make the movement
time),
immediate
closing
15