(inversions, stop, alarms, etc.).
Upon closing the power sensor stops the gate.
4 - AFTER PROGRAMMING RESET DIP 2 TO OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE
AND STOP THE PROGRAMMING PROCEDURE (LED DL1 FROM
FLASHING BECOMES CONSTANT). TO REPEAT PROGRAMMING SET
DIP 2 TO OFF, CLOSE THE GATE USING THE PROCEDURE "MOTOR
ROTATIONAL DIRECTION CONTROL" AND REPEAT THE DESIRED
PROGRAMMING PROCEDURE.
D -
SETTING THE TIME FOR 2 MOTORS (#) WITH TIME
OPERATION (DIP 7 OFF)
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button. => M1 opens.
4 - When the mechanical opening stop is reached, wait a second then press
the PROG button => M1 stops and M2 opens.
5 - When the mechanical opening stop is reached => wait 1 second and
press the PROG button => M2 stops.
6 - Press the PROG button => M2 closes.
7 - Press the PROG button => M1 closes setting the time lag between M2
and M1.
At the same time LED DL1 stops flashing indicating exit from the
programming procedure.
Safety and other gate commands now operate normally (inversions,
stop, alarms, etc.).
8 - After the set amount of time, the gate will stop.
9 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.
NOTE: The slowdown is automatically determined by the control board
during the time setting phase and is activated at about 50 to 60 cm before
reaching the mechanical opening or closing limit.
D -
SETTING THE TIME FOR 1 MOTOR (#) WITH TIME
OPERATION (DIP 7 OFF)
CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST SET TO ON
1 - The gate must be completely closed.
2 - Set micro-switch DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button => M1 opens.
4 - When the mechanical opening stop is reached, wait a second then press
the PROG button => M1 stops.
5 - Press the PROG button => M1 closes.
At the same time LED DL1 stops flashing indicating exit from the
programming procedure.
Safety and other gate commands now operate normally (inversions,
stop, alarms, etc.).
6 - After the set amount of time, the gate will stop.
7 - AT THE END OF PROGRAMMING RESET DIP 2 TO OFF.
D -
SETTING PEDESTRIAN OPENING TIMES (#) BOTH FOR TIME
AND POWER SENSOR OPERATION
With gate closed:
1 - First set DIP2 to ON (LED DL1 flashes quickly) and then DIP1 to ON (
LED DL1 flashes slowly).
2 - Push the pedestrian button (COM-PED.BUTT) => M1 opens.
3 - Push the pedestrian button to stop movement (thereby setting M1
opening).
4 - Push the pedestrian button to start closing.
5 - Upon closing reset DIP 1 and 2 to OFF.
(#) DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE
AND STOP THE PROGRAMMING PROCEDURE (LED DL1 FROM
FLASHING BECOMES CONSTANT).
TO REPEAT PROGRAMMING SET DIP 2 TO OFF, CLOSE THE
GATE USING THE PROCEDURE "MOTOR ROTATIONAL DIRECTION
CONTROL" AND REPEAT THE DESIRED PROGRAMMING PROCEDURE.
E -
RADIO CODE PROGRAMMING FOR TOTAL OPENING
(UP TO 40 CODES)
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON.
2 - The red LED DL1 flashes ON every 1 sec. and OFF for 10 seconds.
3 - Press the remote control button (usually channel A) within the allotted 10
seconds. If the remote is memorized properly LED DL10 (green) blinks.
4 - The programming time for codes is automatically renewed in order to
14
All manuals and user guides at all-guides.com
memorize the next remote control.
5 - To finish programming, wait 10 seconds, or press the PROG button
briefly. The red LED DL1 stops flashing.
6 - Reset DIP 1 to OFF and DIP 2 to OFF.
7 - End of procedure.
CANCELLATION OF ALL RADIO CODES FOR TOTAL OPENING
Cancellations can only be performed when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The red LED DL1 flashes ON every 1 second and OFF for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is
indicated by two flashes of green LED DL10.
4 - The red LED DL1 remains active and you can add new codes as shown
above.
5 - Reset DIP 1 to OFF and DIP 2 to OFF.
6 - End of procedure.
INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING
Indication only when gate is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The green LED DL10 flashes 6 times when the memory is full (40
codes).
3 - LED DL1 will then remain active for 10 seconds enabling possible
cancellation of codes.
4 - Reset DIP 1 to OFF and DIP 2 to OFF.
5 - End of procedure.
F -
PROGRAMMING PEDESTRIAN OPENING RADIO CODES
(UP TO 40 CODES)
Programming can be done only when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The red led DL1 flashes ON for 1 second and OFF for 1 second for 10
seconds.
3 - Press the remote control button (usually channel B) within the allotted 10
seconds. If the remote is properly memorized LED DL10 (green) blinks.
4 - The programming time for codes is automatically renewed in order to
memorize the next remote control.
5 - To finish programming wait 10 seconds, or press the PROG button
briefly. The red LED DL1 stops flashing.
6 - Reset DIP 1 to OFF and DIP 3 to OFF.
NOTE: If LED DL1 CONTINUES BLINKING QUICKLY IT MEANS
THAT DIP 1 IS STILL SET TO ON AND THAT ANY OPERATION IS
REFUSED.
7 - End of procedure.
CANCELLATION PROCEDURE FOR ALL PEDESTRIAN OPENING
RADIO CODES
Cancellation can only be performed when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The red LED DL1 flashes ON for 1 second and OFF for 1 second for
10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is
indicated by two flashes of green LED DL10.
4 - The red LED DL1 remains active and you can add new codes as shown
above.
5 - Reset DIP 1 to OFF and DIP 3 to OFF.
6 - End of procedure.
INDICATION MEMORY FULL OF PEDESTRIAN OPENING RADIO
CODES
Indication only when the gate is stationary.
1 - Set DIP 1 to ON and then DIP 3 to ON.
2 - The green LED DL10 flashes 6 times when the memory is full (40
codes).
3 - The LED DL1 will then remain active for 10 seconds enabling possible
cancellation of codes.
4 - Set DIP 1 to OFF and DIP 3 to OFF.
5 - End of procedure.