B -
SETTINGS
DIP 1
(ON) - MOTOR ROTATION DIRECTION CONTROL (POINT C)
DIP 2
(ON) - TIMER (POINT D)
DIP 3
(ON) - ACTIVATES DOOR RELEASE DURING PHASES OF
SLOWDOWN AND TOTAL OPENING AND CLOSING (AS PER
THE IMPACT TESTS OF EN12453)
DIP 1-2 MEMORIZATION/CANCELLATION OF RADIO CONTROL
CODES FOR TOTAL OPENING (POINT E)
DIP 1-3 MEMORIZATION/CANCELLATION OF RADIO CONTROL
CODES FOR PEDESTRIAN OPENING (POINT F)
DIP 2-1 MICRO-SWITCH CONTROLLER FOR PEDESTRIAN OPENING
TIMER
DIP 4
Photocells always active (OFF) - Photocells active only during
closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (K BUTT) and step-by-step radio receiver
(OFF) - automatic (ON)
DIP 7
Power sensor operation (ON-activated) time operation (OFF-
activated).
DIP 8
Electric lock activation (ON-activated)
DIP 9
Electric lock pulse release (ON-activated)
DIP 10 Electric lock pulse engagement (ON-activated)
DIP 11 Easy release activation (ON-activated)
DIP 12 Sensor TEST activation (ON-activated).
DIP 13 Selection of 1 or 2 motor operation (default OFF 2 motors)
DIP 14 OFF EKKO ART 200D WITH ELECTRIC LOCK
ON EKKO ART 200D WITHOUT ELECTRIC LOCK
DIP 15 ON
DIP 16 IMMEDIATE CLOSING AFTER PASSING IN FRONT OF
PHOTOCELLS
ON
ACTIVATED
OFF
DEACTIVATED
JP1 => Check that the jumper is inserted!
JP2 => Check that the jumper is inserted!
JP3 => Check that the jumper is inserted!
PROG => S3 Programming button
A
DJUSTMENTS
ATTENTION: PUT DIP 3 IN THE ON MODE ONLY AFTER HAVING
CARRIED OUT ALL THE PROGRAMMING PROCEDURES.
NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS
ACTIVATED.
THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE
REDUCED TO ZERO WITHIN 5 SECONDS AS PER STANDARD EN12453
POINT A.2.2 (ACCEPTABLE STATIC FORCE), THEREBY COMPLYING
WITH THE IMPACT TESTS ALSO OUTLINED BY EN12453).
IF COMPLIANCE WITH THE AFOREMENTIONED STANDARD IS
UNNECESSARY, SIMPLY POSITION DIP 3 TO OFF. IN THIS CASE THE
GATES STOP WITHOUT REVERSING.
RUN TRIMMER (TR1) high-speed electronic regulator
This trimmer permits motor speed adjustment (the default setting is
maximum speed). Adjustment of the automation is useful for compliance
with European impact standards.
LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control
The slow speed control is performed by adjusting the LOW- SPEED
TRIMMER which changes the voltage output across the motor(s) (turning it
clockwise increases the speed). Adjustment is performed to determine the
correct speed at the end of opening and closing according to the gate or
when there is friction that might cause the system to function poorly.
AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN
default NOT ACTIVATED and LED DL6 OFF (TRIMMER FULLY
ROTATED COUNTERCLOCKWISE)
This trimmer makes it possible to adjust the time for total or pedestrian
automatic closing. Only with gate completely (total) or partially (pedestrian)
open and LED DL6 on (trimmer rotated clockwise).
The pause time can be adjusted from a minimum of two seconds up to a
maximum of two minutes.
EN
All manuals and user guides at all-guides.com
LED SIGNALS
DL1 program activated (red)
DL2 gate opening M2 (green)
DL3 gate closing M2 (red)
DL4 gate opening M1 (green)
DL5 gate closing M1 (red)
DL6 automatic closing indicator (red)
DL7 photocell contact (NC) (red)
DL8 sensor contact (NC) (red)
DL9 STOP button (NC) (red)
DL10 radio code program (green)
FUSES
Fuse 1 T 8A MOTOR PROTECTION FUSE
F1 T 2A
TRANSFORMER PROTECTION FUSE (on the outside of the
RS12 board)
C -
MOTOR ROTATIONAL DIRECTION CONTROL
1 - Set DIP 1 to ON => LED DL1 starts flashing.
2 - Press and hold the PROG button. (movement is now manually
controlled - open-stop-close-stop-open - etc.) => GREEN LEDS DL2
and DL4 are lit and the gate panels open with a fixed lag of 2 sec. If
they close instead of open, release the button and reverse the two wires
on the motor used.
3 - After opening release the PROG button and calibrate the mechanical
opening stops (on the operator).
4 - Press and hold the PROG button => RED LEDs DL3 and DL5 turn on
and the gate panels close with a time lag of 2 sec.
5 - Continue to hold the PROG button until the gate is completely closed.
6 - Leave the two doors completely closed to set the timer.
7 - Reset DIP1 to OFF => LED DL1 turns off, signaling exit from control.
N.B.: During this check the stop, the photocells and the sensors are
not active.
D -
SETTING THE TIMER FOR 2 MOTORS (#) WITH POWER
SENSOR ACTIVATED (DIP 7 ON)
WHILE SETTING THE TIMER THE POWER SENSOR IS CONTINUOUSLY
ACTIVATED.
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will blink rapidly.
3 - Press the PROG button. => M1 opens.
4 - When the mechanical opening stop is reached, the AUTOMATIC
POWER SENSOR stops M1 (memorizing the time and the power) =>
At the same time M2 is triggered to open.
5 - When the mechanical opening stop is reached, the AUTOMATIC
POWER SENSOR stops M2 (memorizing the time and the power).
6 - Press the PROG button. => M2 closes.
7 - Press the PROG button. => M1 closes and sets the lag time between M2
and M1. At the same time LED DL1 stops flashing indicating exit from
the programming procedure.
Safety and other gate commands now operate normally (inversions,
stop, alarms, etc.).
8 - The gate panels will close in high-speed mode (depending on how
you set the RUN trimmer) and near total closure in the slow mode
(depending on how you set the LOW-SPEED trimmer).
9 - Upon closing the power sensors stop the gate.
10 - AFTER PROGRAMMING RESET DIP 2 TO OFF.
D -
SETTING THE TIME FOR ONE MOTOR (M1) (#) WITH
POWER SENSOR ACTIVATED (DIP 7 ON)
CAUTION: FOR ONE MOTOR CONTROL DIP 13 MUST BE POSITIONED
TO ON; DURING PROGRAMMING THE POWER SENSOR IS
CONTINUOUSLY ACTIVE.
The gate must be completely closed.
1 - Set DIP 2 to ON => LED DL1 will blink rapidly.
2 - Press the PROG button. => M1 opens.
When the mechanical opening stop is reached, the AUTOMATIC
POWER SENSOR stops M1 (memorizing the time and the power).
3 - Press the PROG button. => M1 closes.
At the same time LED DL1 stops flashing indicating exit from
programming. Safety and other gate commands now operate normally
13