Models Starting Serial No. 0909
Cool Down Per Cycle
(in minutes)
3 (preset at factory)
6
Total Cycle Time = Heat Time + Cool Down Time
Test Setting
When testing coin slide operation or other
troubleshooting, set dipswitch with this shorter cycle:
1. Unplug the machine power cord.
2. Record the machine control dipswitch settings.
Then set them all to the off position. Refer to
Figure 25.
3. Plug in the machine and initiate a cycle.
512686
Table 6 (continued)
Cool Down
Switch Number
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
OFF
ON
Table 6
NOTE: With all the control dipswitches off, the
total cycle time will be four minutes long.
4. Once all the testing is complete, unplug the
machine and re-set the dipswitches to their
original settings.
5. Plug in the machine.
1 2 3 4 5 6 7 8
O
N
Figure 25
Vending
Cycle Reset
Switch Number
8
OFF
ON
DRY2225P
DRY2225P