Alliance Laundry Systems 0908 Installation page 21

Publicité

Les langues disponibles

Les langues disponibles

Gas Dryers
(120 Volt, 60 Hertz, With 3-Prong Grounding
Plug)
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
WARNING
To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
to the dryer unit MUST conform with the
local codes, or in the absence of local
codes, with the latest edition of the
National Electrical Code ANSI/NFPA 70 or
the Canadian Electrical Code, CSA C22.1,
and such local regulations as might
apply. It is the customer's responsibility
to have the wiring and fuses checked by a
qualified electrician to make sure the
laundry room has adequate electrical
power to operate the dryer unit.
• Each dryer is designed to be operated on a
separate branch, polarized, three-wire, effectively
grounded, 120 Volt, 60 Hertz, AC (alternating
current) circuit protected by a 20 Ampere fuse,
equivalent fusetron or circuit breaker.
• The three-prong grounding plug on the power
cord should be plugged directly into a polarized
three-slot effectively grounded receptacle rated
120 Volts AC (alternating current) 20 Amps.
Refer to Figure 21 to determine correct polarity
of the wall receptacle.
WARNING
This dryer is equipped with a three-prong
(grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
three-prong receptacle. Do not cut or
remove the grounding prong from this
plug.
512686
W084
W036
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
5
115 ± 12
V.A.C.
4
STANDARD 120 VOLT, 60 HERTZ,
3-WIRE EFFECTIVELY GROUNDED CIRCUIT
1
L1
2
Ground
3
Neutral
4
Round Grounding Prong
5
Neutral Side
Figure 21
NOTE: A qualified electrician should check the
polarity of the wall receptacles. If a voltage reading
is measured other than that illustrated, the
qualified electrician should correct the problem.
• DO NOT OPERATE OTHER APPLIANCES
ON THE SAME CIRCUIT WHEN THIS
APPLIANCE IS OPERATING. DO NOT
OVERLOAD CIRCUITS! Refer to Figure 22.
.
DO NOT
OVERLOAD
CIRCUITS
Figure 22
WARNING
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the dryer unit to the
electrical power source.
Installation
2
3
0
V.A.C.
115 ± 12
V.A.C.
D739I
D739I
D009I
W152
19