Installation
Installing the Dryer
Step 1: Position and Level the Dryer
Install dryer before washer. This allows room for
attaching exhaust duct.
Install the four rubber feet (in accessories bag).
Select a location with a solid floor. Dryers installed in
residential garages must be elevated 46 cm (18 inches)
above the floor.
NOTE: Shaded areas indicate adjacent structure.
Area
A
B
C
D
E
8
A
A
Dryer and Exhaust Duct Clearances
Description
Dryer Sides
Dryer Top (Rear 24 in.)
Dryer Rear
Dryer Top (Front 4 in.)
Exhaust Duct from Combustible Construction
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
No other fuel burning appliance should be installed in
the same closet with the dryer.
The dryer unit must not be installed or stored in an
area where it will be exposed to water and/or weather.
The dryer needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown in Figure 2).
D
Figure 2
B
C
E
E
D358I
Minimum Clearance
0 cm (0 in.)
30.5 cm (12 in.)
10.2 cm (4 in.)
1.3 cm (0.5 in.)
5.1 cm (2 in.)
D358I
512686