After either dryer has operated for approximately five
minutes, observe burner flame through lower front
panel. Adjust the air shutter to obtain a soft, uniform
blue flame. (A lazy, yellow-tipped flame indicates lack
of air. A harsh, roaring, very blue flame indicates too
much air.) Adjust the air shutter as follows:
1. Loosen the air shutter lockscrew.
2. Turn the air shutter to the left to get a luminous
yellow-tipped flame, then turn it back slowly to
the right to obtain a steady, soft blue flame.
3. After the air shutter is adjusted for proper flame,
tighten the air shutter lockscrew securely.
4. Reinstall the lower front panel.
COIN SLIDE, MDC, AND NETMASTER MODELS THROUGH
SERIAL NO. 0803 AND NONMETERED MODELS
1
6
5
1
Closed Position
2
Shut-Off Valve Handle
3
Air Shutter Lockscrew
4
Air Shutter
512686
2
3
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
For personal safety, lower front panel must
be in place during normal operation.
After either dryer has operated for approximately three
minutes, exhaust air or exhaust pipe should be warm.
COIN SLIDE, MDC, AND NETMASTER MODELS
STARTING SERIAL NO. 0804
1
6
5
D700I
5
3.1 mm (1/8 in.) Pipe Plug
(For checking manifold pressure)
6
Open Position
Figure 23
Installation
WARNING
2
W046
3
4
DRY2235N
21