5
B
A
30°
1
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening must be
sized per local codes.
2
Wall
.
2
1
CONNECT TO DRYER
4
VERTICAL EXHAUST INSTALLATION
1
Roof
2
Wall
3
5 cm (2 in.) Minimum
4
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, an opening must
be sized as shown or per local codes.
Figure 7
512686
C
D
E
F
G
H
HORIZONTAL EXHAUST INSTALLATION
3
H319I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
K
1
I
J
AIR
FLOW
EXHAUST AIR FLOW
MAXIMUM LENGTH OF
DUCT 9.1 m (30 feet)
3
Clearance per Local Codes
4
No Screen or Cap
5
Clean Out Cover – Inspect Monthly
Figure 6
To reduce the risk of fire and the
accumulation of combustion gases, DO NOT
exhaust dryer air into a window well, gas
vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
of a building.
Installation
2
3
4
EXHAUST
OUTLET
WARNING
H318I
W045
13